	<entry>
		<id>https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=829&amp;oldid=prev</id>
		<title>Monica Hurley: Revision 0; Reviewed by Garry Young</title>
		<link rel="alternate" type="text/html" href="https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=829&amp;oldid=prev"/>
		<updated>2024-10-10T14:46:40Z</updated>

		<summary type="html">&lt;p&gt;Revision 0; Reviewed by Garry Young&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 14:46, 10 October 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{DISPLAYTITLE:Examples of AMP with Changes as a Result of GALL Revision}}&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{DISPLAYTITLE:Examples of AMP with Changes as a Result of GALL Revision}}&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt; &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;===XI.M19 – Steam Generator Tube Integrity===&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;===XI.M19 – Steam Generator Tube Integrity===&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01 -  “Changes to Aging Management Guidance for Various Steam Generator Components”], includes a revision to [[1801_R2_XI.M19| XI.M19 in GALL Rev. 2]] to address the aging management guidance on loss of material due to boric acid corrosion of steam generator heads and tubesheets. [[1801_R2_XI.M19| XI.M19]] now includes steam generator primary side internal surfaces and dictates that visual inspections of these surfaces should be performed at least every 72 effective full power months or every third refueling outage (whichever results in more frequent inspections). The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01] was incorporated into the [[2191_R0_XI.M19| XI.M19 AMP description in NUREG-2191/2192, Revision 0]] for subsequent license renewal.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01 -  “Changes to Aging Management Guidance for Various Steam Generator Components”], includes a revision to [[1801_R2_XI.M19| XI.M19 in GALL Rev. 2]] to address the aging management guidance on loss of material due to boric acid corrosion of steam generator heads and tubesheets. [[1801_R2_XI.M19| XI.M19]] now includes steam generator primary side internal surfaces and dictates that visual inspections of these surfaces should be performed at least every 72 effective full power months or every third refueling outage (whichever results in more frequent inspections). The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01] was incorporated into the [[2191_R0_XI.M19| XI.M19 AMP description in NUREG-2191/2192, Revision 0]] for subsequent license renewal.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Monica Hurley</name></author>
	</entry>
	<entry>
		<id>https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=457&amp;oldid=prev</id>
		<title>Monica Hurley: 1 revision imported: Initial page creation</title>
		<link rel="alternate" type="text/html" href="https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=457&amp;oldid=prev"/>
		<updated>2024-10-04T19:12:24Z</updated>

		<summary type="html">&lt;p&gt;1 revision imported: Initial page creation&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 19:12, 4 October 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;en&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Monica Hurley</name></author>
	</entry>
	<entry>
		<id>https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=456&amp;oldid=prev</id>
		<title>en&gt;Monica Hurley: /* XI.M27 Fire Water System */</title>
		<link rel="alternate" type="text/html" href="https://LTO.epri.com/index.php?title=AMP_Changes&amp;diff=456&amp;oldid=prev"/>
		<updated>2024-09-11T13:23:56Z</updated>

		<summary type="html">&lt;p&gt;&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;XI.M27 Fire Water System&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{DISPLAYTITLE:Examples of AMP with Changes as a Result of GALL Revision}}&lt;br /&gt;
&lt;br /&gt;
===XI.M19 – Steam Generator Tube Integrity===&lt;br /&gt;
Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01 -  “Changes to Aging Management Guidance for Various Steam Generator Components”], includes a revision to [[1801_R2_XI.M19| XI.M19 in GALL Rev. 2]] to address the aging management guidance on loss of material due to boric acid corrosion of steam generator heads and tubesheets. [[1801_R2_XI.M19| XI.M19]] now includes steam generator primary side internal surfaces and dictates that visual inspections of these surfaces should be performed at least every 72 effective full power months or every third refueling outage (whichever results in more frequent inspections). The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2016-01] was incorporated into the [[2191_R0_XI.M19| XI.M19 AMP description in NUREG-2191/2192, Revision 0]] for subsequent license renewal.&lt;br /&gt;
&lt;br /&gt;
===XI.M41 Buried and Underground Piping and Tanks===&lt;br /&gt;
Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2011-03 – “Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, ‘Buried and Underground Piping and Tanks’”], revised inspection recommendations for [[1801_R2_XI.M41| GALL Rev. 2 XI.M41]] along with the addition of acceptance criteria for cathodic protection surveys. [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2015-01 – “Changes to Buried and Underground Piping and Tank Recommendations”], replaced [[1801_R2_XI.M41| GALL Rev. 2 AMP Report XI.M41]] and associated UFSAR Summary Description in [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2011-03]. The recommendations provided by the established guidance for [[2191_R0_XI.M41| XI.M41]] modified inspections and testing being performed along with several elements such as the scope and acceptance criteria of [[2191_R0_XI.M41| XI.M41]]. Additionally, recommendations related to inspections for selective leaching of buried components were relocated to GALL AMP Report [[2191_R0_XI.M33| XI.M33]]. The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2011-03] and [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2015-01] were incorporated into [https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2191/index.html NUREG 2191]/[https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2192/index.html 2192], Revision 0 for subsequent license renewal.&lt;br /&gt;
&lt;br /&gt;
===XI.M27 Fire Water System===&lt;br /&gt;
Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2012-02 – “Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation”], revised [[1801_R2_XI.M27| GALL Rev. 2 XI.M27]] to include revised recommendations to manage the aging effects applicable to fire water system components such as fire water tanks. Appropriate inspections and tests recommended in NFPA 25 were incorporated into [[1801_R2_XI.M27| XI.M27]]. [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2013-01 – “Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers and Tanks“] revised the [[1801_R2_XI.M27| GALL Rev. 2 XI.M27 AMP]] to manage the aging effects associated with fire water tank internal coatings/linings rather than XI.M42 “Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks”. However, recommendations from GALL Rev. 2 XI.M42 regarding training, qualification of personnel, “corrective actions”, and “acceptance criteria” for coated fire water storage tank internals enhance [[1801_R2_XI.M27| XI.M27]]. The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2012-02] and [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2013-01] were incorporated into [https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2191/index.html NUREG 2191]/[https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2192/index.html 2192], Revision 0 for subsequent license renewal.&lt;br /&gt;
&lt;br /&gt;
===XI.M36 External Surfaces Monitoring of Mechanical Components===&lt;br /&gt;
Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2011-03 – “Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, “Buried and Underground Piping and Tanks”&amp;quot;], revised [[1801_R2_XI.M36| GALL Rev. 2 XI.M36]] due to an internal conflict between [[1801_R1_XI.M36| XI.M36]] and XI.M41 “Buried and Underground Piping and Tanks” resulting in changes to “scope of program” and “detection of aging effects” of [[1801_R1_XI.M36| XI.M36]]. [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2012-02 – “Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation”], revised [[1801_R2_XI.M36| XI.M36]] to address detection of aging effects of tightly adhering insulation and to recommend periodic inspections during each 10-year period of the PEO. To address aging management methods for corrosion under insulation, the established guidance revised [[1801_R2_XI.M36| XI.M36]] to recommend that inspection locations should be based on the likelihood of corrosion under insulation occurring. The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2011-03] and [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2012-02] were incorporated into [https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2191/index.html NUREG 2191]/[https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2192/index.html 2192], Revision 0 for subsequent license renewal.&lt;br /&gt;
&lt;br /&gt;
===XI.M42 – Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks===&lt;br /&gt;
Interim staff guidance (ISG), [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2013-01 – “Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers and Tanks&amp;quot;], created GALL AMP Report XI.M42. Some of the already established GALL Rev. 2 AMP Reports can still be used to manage the aging effects for coatings/linings applied to the internal surfaces of components as long as recommendations from XI.M42 are included. However, aging effects associated with fire water tank internal coatings/linings are managed by [[1801_R2_XI.M27| XI.M27 “Fire Water System”]]. The guidance established by [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html LR-ISG-2013-01] was incorporated into [https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2191/index.html NUREG 2191]/[https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2192/index.html 2192], Revision 0 for subsequent license renewal. [https://www.nrc.gov/reading-rm/doc-collections/isg/license-renewal.html SLR-ISG-2021-02 – “Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance”], revised [[2191_R0_XI.M42| XI.M42 in SLR GALL]] to recommend opportunistic inspections rather than periodic inspections. Environments were also added to the scope of [[2191_R0_XI.M42| XI.M42]].&lt;br /&gt;
&lt;br /&gt;
===XI.E6 – Electrical Cable Connections Not Subject to EQ===&lt;br /&gt;
[https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1801/index.html NUREG-1801], Revision 2 for license renewal recommends one-time testing prior to PEO for aging effects. [https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr2191/index.html NUREG-2191], Revision 0 for subsequent license renewal recommends periodic testing, if warranted, should findings of the initial one-time test find aging effects after performing an evaluation. No impact from interim staff guidance documents.&lt;br /&gt;
&lt;br /&gt;
=Record of Revisions=&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; style=&amp;quot;text-align: left;&amp;quot;&lt;br /&gt;
!Number !! Date !! Description of Changes&lt;br /&gt;
|-&lt;br /&gt;
|0 || 6/11/2024 || Initial version&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>en&gt;Monica Hurley</name></author>
	</entry>