AMPs: Difference between revisions
en>Monica Hurley |
(No difference)
|
Revision as of 17:13, 11 September 2024
Aging Management Programs (AMPs) are created in both the US and internationally to manage aging effects for component types identified during the aging management review (AMR) portion of the integrated plant assessment (IPA) process or the LTO assessment. US NRC previously approved generic AMP descriptions and requirements are included in Chapter XI of the Generic Aging Lessons Learned (GALL) reports for both initial (see NUREG-1801) and subsequent license renewal (SLR) (see NUREG-2191). Plant-specific AMPs may also be created when necessary to manage any unique aging effects or components at a nuclear site or if a plant-specific AMP will more effectively manage the aging effect of interest for that plant.
10 Element Approach[edit]
Whether generic or plant-specific, an AMP must include ten elements that serve as the technical basis for the program. These elements are:
- Scope of Program
- Preventive Actions
- Parameters Monitored or Inspected
- Detection of Aging Effects
- Monitoring and Trending
- Acceptance Criteria
- Corrective Actions
- Confirmation Process
- Administrative Controls
- Operating Experience
AMPs can also include pre-existing plant programs with or without enhancements or have exceptions.
Element 1 provides the direct connection to the AMR through the definition of component types, structures, or specific materials, environments, or aging effects that will be managed by a particular AMP.
Elements 2 through 5 provide a means to prevent, identify, and disposition aging of components and to expand the scope of the program, should significant aging be detected. These elements include provisions for recommended inspection types, frequency, and sample size, as well as applicable mitigative actions.
Elements 6 through 8 provide guidance regarding acceptable practices for dispositioning identified aging, including extent of condition and recommended actions. These elements ensure that aging effects which exceed acceptance criteria are appropriately entered into the site’s corrective action program. Entering identified age-related degradation into the corrective action program ensures that:
- The resolution of that specific degradation is tracked.
- Timely action can be taken to identify and prevent or mitigate further and future aging in related SSCs before the degradation challenges the intended function of the components.
- Corrective actions are adequate and effective.
Element 9 provides a link to a site’s existing quality assurance program, ensuring that administrative controls provide a formal review and approval process for actions related to a given AMP.
Element 10 outlines the obligation to continuously review and disposition both industry and plant-specific operating experience related to the other elements of a given AMP.
Disposition of, and consistency with, each of the ten elements for a specific AMP at a given site forms the basis for adequate aging management of LR components. Therefore, any exceptions or enhancements to the guidance within the applicable Generic Aging Lessons Learned (GALL) report for a generic AMP element must be appropriately identified and justified for regulatory review and acceptance during the license renewal application (LRA) process.
Existing vs New AMPs:
Existing programs are programs at a NPP which are currently being implemented and very closely align with the AMP as described in the GALL Report. These existing site programs are credited as the LR AMP upon entering the period of extended operation (PEO). An existing site program can become an LR AMP with no changes or with enhancements and/or exceptions. Some examples of existing programs often credited for LR include: Underground Piping and Tanks, Flow Accelerated Corrosion, Fire Protection, and ASME Section XI, Subsection IWE.
New AMPs are created as a result of the LR integrated plant assessment (IPA) process to manage specific SSC’s and aging mechanisms that an existing plant program does not or cannot be modified to effectively meet the requirements or intent of a LR AMP as described in the GALL Report.
Enhancements are changes made to an existing plant program being credited as a license renewal AMP. These changes are made:
- To ensure consistency with the ten elements of the generic AMP as described in the applicable GALL report, or
- As a result of operating experience (OE) reviews.
Enhancements are annotated in the license renewal application (LRA) and in the Safety Evaluation Report (SER) issued by the US NRC. Typically, enhancements are treated as LR commitments.
Exceptions are intentional deviations from the generic ten elements of an AMP as described in the applicable GALL report. These deviations may be due to the unique configuration or design of a plant (e.g. equipment functions, plant layout, materials, environments, etc.) or the result of site specific OE. Exceptions are annotated in the LRA and in the Safety Evaluation Report (SER) issued by the US NRC.
GALL AMP Descriptions[edit]
The GALL Report and its corresponding Standard Review Plan (SRP), issued by the US NRC, have gone through several revisions since their initial issuance in 2001. These documents essentially lay a framework for LR application development, and subsequently the development of AMPs. Like the guidance documents themselves, the AMPs have also evolved over time to incorporate items such as industry OE, revised codes and standards, and new aging mechanisms. The table below, contains the AMP descriptions contained in each GALL revision for both initial LR and subsequent LR (SLR).
Click here for information on AMPs with significant changes as a result of GALL revision.
Operating Experience[edit]
To ensure adequate management of aging mechanisms, AMPs must exist in a constant feedback loop in which OE (industry and plant-specific) is reviewed, considered, and used to either improve the AMP or justify the existing conduct of the program.
- NEI 14-12, “Aging Management Program Effectiveness” is the industry standard used to periodically assess the effectiveness of each plant AMP. AMP effectiveness reviews should be performed at a minimum recommended typical frequency of every five years within the period of extended operation (PEO). These self-performed effectiveness reviews/self-assessments typically coincide with and/or provide readiness for the US NRC IP-71003 - "Post-Approval Site Inspection for License Renewal" (Phase IV Inspection) conducted within the first five to ten years of the PEO.
- NEI 14-13 “Use of OE for Age-Related Degradation and AMPs” details a methodology for screening and evaluating operating experience and incorporating this OE into an AMP, if deemed necessary. It also provides an industry approach for the review and sharing of OE pertaining to age-related degradation of SSC’s.
- As newer revisions of the GALL report are issued, plants are responsible for identifying and evaluating “gaps” between the version of the GALL report that was the latest version when the initial AMP was developed, and the new standard set forth in the updated GALL report. AMPs may be revised if the latest version of the GALL report identifies changes that are appropriate for the plant. Note: GALL gap-analysis for a specific AMP can result in an increase or decrease in requirements for AMP implementation.
EPRI References for AMPs[edit]
| GALL-SLR AMPs | Key EPRI Guidance Documents | Title | Key ISG's |
|---|---|---|---|
| X.M2 - Neutron Fluence Monitoring | SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance (Addresses 2020 Errata) | ||
| X.S1 - Concrete Containment Unbonded Tendon Prestress | |||
| X.E1 - Environmental Qualification (EQ) of Electric Components | |||
| XI.M1 - ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD | 1019075 | TR-105696-R12 (BWRVIP-03) Revision 12: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |
| XI.M2 - Water Chemistry | 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance (Addresses 2020 Errata) |
| 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | ||
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | ||
| XI.M3, "Reactor Head Closure Stud Bolting" | |||
| XI.M4, "BWR Vessel ID Attachment Welds" | 1019075 | TR-105696-R12 (BWRVIP-03) Revision 12: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | ||
| 1009948 | BWRVIP-48-A: BWR Vessel and Internals Project, Vessel ID Attachment Weld Inspection and Flaw Evaluation Guidelines | ||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | ||
| 1008871 | BWRVIP-60-A: BWR Vessel and Internals Project, Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | ||
| 3002014434 | BWRVIP-62-A (2018 Update): BWR Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | ||
| XI.M7, "BWR Stress Corrosion Cracking" | 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | ||
| 1008871 | BWRVIP-60-A: BWR Vessel and Internals Project, Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | ||
| 3002014434 | BWRVIP-62-A (2018 Update): BWR Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | ||
| TR-112076 | Induction Heating Stress Improvement Effectiveness on Crack Growth in Operating Plants (BWRVIP-61) | ||
| 1012621 | BWRVIP-75-A: BWR Vessel and Internals Project, Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules | ||
| XI.M8, "BWR Penetrations" | 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |
| 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | ||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | ||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | ||
| 1007279 | BWRVIP-27-A: BWR Vessel and Internals Project, BWR Standby Liquid Control System / Core Plate Delta-P Inspection and Flaw Evaluation Guidelines | ||
| 1009947 | BWRVIP-47-A: BWR Vessel and Internals Project, BWR Lower Plenum Inspection and Flaw Evaluation Guidelines | ||
| 1006602 | BWRVIP-49-A: BWR Vessel and Internals Project, Instrument Penetration Inspection and Flaw Evaluation Guidelines | ||
| 1012120 | BWRVIP-53-A: BWR Vessel and lnternals Project, Standby Liquid Control Line Repair Design Criteria | ||
| 3002020995 | BWRVIP-57, Revision 1: BWR Vessel and Internals Project—Instrument Penetration Repair Design Criteria | ||
| XI.M9, "BWR Vessel Internals" | 1019075 | TR-105696-R12 (BWRVIP-03) Revision 12: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | ||
| 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | ||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | ||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | ||
| 1008871 | BWRVIP-60-A: BWR Vessel and Internals Project, Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | ||
| 3002014434 | BWRVIP-62-A (2018 Update): BWR Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | ||
| 1009947 | BWRVIP-47-A: BWR Vessel and Internals Project, BWR Lower Plenum Inspection and Flaw Evaluation Guidelines | ||
| 3002020995 | BWRVIP-57, Revision 1: BWR Vessel and Internals Project—Instrument Penetration Repair Design Criteria | ||
| 1012837 | BWRVIP-02-A: BWR Vessel and Internals Project, BWR Core Shrould Repair Design Criteria, Rev. 2 | ||
| 1012113 | BWRVIP-16-A: BWR Vessel and Internals Project, Internal Core Spraying Piping and Sparger Replacement Design Criteria | ||
| 3002008089 | BWRVIP-18, Revision 2-A: BWR Vessel and Internals Project, BWR Core Spray Internals Inspection and Flaw Evaluation Guidelines | ||
| 1012114 | BWRVIP-19-A: BWR Vessel and Internals Project, Internal Core Spray Piping and Sparger Repair Design Criteria | ||
| 3002018310 | BWRVIP-25, Rev. 1-A, BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines | ||
| 1009946 | BWRVIP-26-A: BWR Vessel and Internals Project, BWR Top Guide Inspection and Flaw Evaluation Guidelines | ||
| TR-108823 | BWR Vessel and Internals Project: BWR Shroud Support Inspection and Flaw Evaluation Guidelines (BWRVIP-38) | ||
| 3002014254 | BWRVIP-41, Revision 4-A BWR Vessel and Internals Project: Jet Pump Assembly Inspection and Flaw Evaluation Guidelines | ||
| 3002010548 | BWRVIP-42, Revision 1-A: BWR Vessel and Internals Project, Low Pressure Coolant Injection (LPCI) Coupling Inspection and Flaw Evaluation Guidelines | ||
| 1014352 | BWRVIP-44-A: BWR Vessel and Internals Project: Underwater Weld Repair of Nickel Alloy Reactor Vessel Internals | ||
| TR-108707 | BWR Vessel and Internals Project: Weldability of Irradiated LWR Structural Components (BWRVIP-45) | ||
| 1012115 | BWRVIP-50-A: BWR Vessel and Internals Project, Top Guide/Core Plate Repair Design Criteria | ||
| 1012116 | BWRVIP-51-A: BWR Vessel and Internals Project, Jet Pump Repair Design Criteria | ||
| 1012119 | BWRVIP-52-A: BWR Vessel and Internals Project, Shroud Support and Vessel Bracket Repair Design Criteria | ||
| 1012118 | BWRVIP-56-A: BWR Vessel and Internals Project, LPCI Coupling Repair Design Criteria | ||
| 1012618 | BWRVIP-58-A: BWR Vessel and Internals Project, CRD Internal Access Weld Repair | ||
| 3002000650 | BWRVIP-278: BWR Vessel and Internals Project, Technical Bases for Revision of the BWRVIP-76 Core Shroud Inspection Program | ||
| 1015457 | BWRVIP-80-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Shroud Vertical Welds | ||
| 1016566 | BWRVIP-99-A: BWR Vessel and Internals Project, Crack Growth Rates in Irradiated Stainless Steels in BWR Internal Components | ||
| 3002010541 | BWRVIP-139, Revision 1-A: BWR Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines | ||
| 3002018319 | BWRVIP-167, Revision 4: BWR Vessel and Internals Project, Boiling Water Reactor Issue Management Tables | ||
| 3002010551 | BWRVIP-183-A: BWR Vessel and Internals Project, Top Guide Grid Beam Inspection and Flaw Evaluation Guidelines | ||
| 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | ||
| XI.M10, "Boric Acid Corrosion" | |||
| XI.M11B, "Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components (PWRs Only)" | |||
| XI.M12, "Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS)" | 1019075 | TR-105696-R12 (BWRVIP-03) Revision 12: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance (Addresses 2020 Errata) |
| XI.M16A, "PWR Vessel Internals" | 3002017168 | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227, Revision 1-A) | |
| 3002026460 | Materials Reliability Program: Inspection Standard for Pressurized Water Reactor Internals - 2023 Update (MRP-228, Rev. 5) | ||
| XI.M17, "Flow-Accelerated Corrosion" | 3002000563 | Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R4) | LR-ISG-2012-01, Wall Thinning Due to Erosion Mechanisms |
| XI.M18, "Bolting Integrity" | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
|
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | ||
| XI.M19, "Steam Generators" | 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | LR-ISG-2011-02, Aging Management Program for Steam Generators LR-ISG-2016-01, Changes to Aging Management Guidance for Various Steam Generator Components |
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | ||
| 3002018267 | Steam Generator Management Program: PWR Primary-to-Secondary Leak Guidelines-Revision 5 | ||
| 3002020909 | Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines, Revision 5 | ||
| 3002007572 | Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 8 | ||
| 3002007856 | Steam Generator Management Program: Steam Generator In Situ Pressure Test Guidelines, Revision 5 | ||
| XI.M20, "Open-Cycle Cooling Water System" | 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks |
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | ||
| XI.M21A, "Closed-Cycle Cooling Water Systems" | 3002000590 | Closed Cooling Water Chemistry Guideline: Revision 2 | LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance (Addresses 2020 Errata) |
| XI.M22, "Boraflex Monitoring" | NP-6159 | An Assessment of Boraflex Performance in Spent-Nuclear-Fuel Storage Racks | |
| 1003413 | Guidance and Recommended Procedures for Maintaining and Using RACKLIFE Version 1.10 Models | ||
| TR-101986 | Boraflex Test Results and Evaluation | ||
| TR-103300 | Guidelines for Boraflex Use in Spent-Fuel Storage Racks | ||
| XI.M23, "Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems" | |||
| XI.M24, "Compressed Air Monitoring" | 3002022576 | Compressed Air Systems and Equipment Guide: Update and Consolidation of TR-108147 and 1006677 | LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks |
| XI.M25, "BWR Reactor Water Cleanup System" | |||
| XI.M26, "Fire Protection" | |||
| XI.M27, "Fire Water System" | LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks | ||
| XI.M29, "Outdoor and Large Atmospheric Metallic Storage Tanks" | LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks | ||
| XI.M30, "Fuel Oil Chemistry" | LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks | ||
| XI.M31, "Reactor Vessel Material Surveillance" | Materials Reliability Program (MRP) - Materials Research Focus Area(MRFA)4- Low Alloy Steels Wiki | Materials Research Focus Area (MRFA)4 - Low Alloy Steels | |
| 3002020910 | Materials Reliability Program: Coordinated PWR Reactor Vessel Surveillance Program (CRVSP) Guidelines (MRP-326, Revision 1) | ||
| 3002007964 | Materials Reliability Program: PWR Supplemental Surveillance Program (PSSP) Capsule Fabrication Report (MRP-412) | ||
| 3002026457 | Materials Reliability Program: Guidance on Timing for Technical Specification Revision Following Surveillance Capsule Testing (MRP-484) | ||
| XI.M32, "One-Time Inspection" | 1019075 | TR-105696-R12 (BWRVIP-03) Revision 12: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |
| XI.M33, "Selective Leaching" | TR-107514 | Age-Related Degradation Inspection Method and Demonstration: In Behalf of Calvert Cliffs Nuclear Power Plant License Renewal Application | LR-ISG-2011-03, Generic Aging Lessons Learned (GALL) Report Revision 2 AMP XI.M41, "Buried and Underground Piping and Tanks" LR-ISG-2015-01, Changes to Buried and Underground Piping and Tank Recommendations |
| XI.M35, "ASME Code Class 1 Small-Bore Piping" | 3002007853 | Materials Reliability Program: Management of Thermal Fatigue in Normally Stagnant Non-Isolable Reactor Coolant System Branch Lines (MRP-146, Revision 2) | |
| 1018330 | Materials Reliability Program: Management of Thermal Fatigue in Normally Stagnant Non-Isolable Reactor Coolant System Branch Lines -Supplemental Guidance (MRP-146S) | ||
| XI.M36, "External Surfaces Monitoring of Mechanical Components" | 1007933 | Aging Assessment Field Guide | LR-ISG-2011-03, Generic Aging Lessons Learned (GALL) Report Revision 2 AMP XI.M41, "Buried and Underground Piping and Tanks" LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation |
| 1009743 | Aging Identification and Assessment Checklist: Mechanical Components | ||
| XI.M37, "Flux Thimble Tube Inspection" | |||
| XI.M38, "Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components" | 1007933 | Aging Assessment Field Guide | LR-ISG-2012-02, Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks |
| 1009743 | Aging Identification and Assessment Checklist: Mechanical Components | ||
| XI.M39, "Lubricating Oil Analysis" | |||
| XI.M40, "Monitoring of Neutron-Absorbing Materials other than Boraflex" | |||
| XI.M41, "Buried and Underground Piping and Tanks" | LR-ISG-2011-03, Generic Aging Lessons Learned (GALL) Report Revision 2 AMP XI.M41, "Buried and Underground Piping and Tanks" LR-ISG-2015-01, Changes to Buried and Underground Piping and Tank Recommendations | ||
| XI.M42, "Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks" | LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks SLR-ISG-2021-02-MECHANICAL, Updated Aging Management Criteria for Mechanical Portions of Subsequent License Renewal Guidance (Addresses 2020 Errata) | ||
| XI.S1, "ASME Section XI, Subsection IWE" | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
|
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | ||
| XI.S2, "ASME Section XI, Subsection IWL" | |||
| XI.S3, "ASME Section XI, Subsection IWF" | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
|
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | ||
| XI.S5, "Masonry Walls" | |||
| XI.S6, "Structures Monitoring" | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
|
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | ||
| XI.S8, "Protective Coating Monitoring and Maintenance" | 1019157 | Plant Support Engineering: Guideline on Nuclear Safety-Related Coatings, Revision 2 (Formerly TR-109937 and 1003102) | |
| XI.E1, "Electrical Insulation for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements" | TR-109619 | Guideline for the Management of Adverse Localized Equipment | |
| XI.E2, "Electrical Insulation for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits" | TR-109619 | Guideline for the Management of Adverse Localized Equipment | |
| XI.E3A, "Electrical Insulation for Inaccessible Medium-Voltage Power Cables Not Subject To 10 CFR 50.49 Environmental Qualification Requirements" | 1013475 | Plant Support Engineering: License Renewal Electrical Handbook | SLR-ISG-2021-04-ELECTRICAL, Updated Aging Management Criteria for Electrical Portions of Subsequent License Renewal Guidance |
| 3002010401 | Long-Term Operations: Subsequent License Renewal Electrical Handbook | ||
| TR-109619 | Guideline for the Management of Adverse Localized Equipment | ||
| XI.E3B, "Electrical Insulation for Inaccessible Instrument and Control Cables Not Subject To 10 CFR 50.49 Environmental Qualification Requirements" | SLR-ISG-2021-04-ELECTRICAL, Updated Aging Management Criteria for Electrical Portions of Subsequent License Renewal Guidance | ||
| XI.E3C, "Electrical Insulation for Inaccessible Low-Voltage Power Cables Not Subject To 10 CFR 50.49 Environmental Qualification Requirements" | 1013475 | Plant Support Engineering: License Renewal Electrical Handbook | SLR-ISG-2021-04-ELECTRICAL, Updated Aging Management Criteria for Electrical Portions of Subsequent License Renewal Guidance |
| 3002010401 | Long-Term Operations: Subsequent License Renewal Electrical Handbook | ||
| TR-109619 | Guideline for the Management of Adverse Localized Equipment | ||
| XI.E4, "Metal-Enclosed Bus" | |||
| XI.E5, "Fuse Holders" | |||
| ' XI.E6, "Electrical Cable Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements" | 3002011484 | Reliability and Maintenance of Bolted Busbar Connections | |
| 1003471 | Electrical Connector Application Guidelines | ||
| TR-109619 | Guideline for the Management of Adverse Localized Equipment | ||
| XI.E7, "High-Voltage Insulators" | SLR-ISG-2021-04-ELECTRICAL, Updated Aging Management Criteria for Electrical Portions of Subsequent License Renewal Guidance |
International Aging Management Programs[edit]
The proven international AMPs are collected by the IAEA Extrabudgetary Programme on International Generic Ageing Lessons Learned (IGALL ) for NPPs. The IGALL has used AMPs in the US NRC’s NUREG-1801 (GALL report) as a reference. IGALL has included aging management operating experience from other plants with different technologies (WWER, CANDU) than those already incorporated in NUREG-1801 (PWR and BWR). Furthermore, new AMPs focused on components (e.g., reactor coolant pump, pressurizer, safety related valves) have been introduced to reflect approaches to aging management followed in other countries. Owing to this, the IGALL offers more alternative AMPs for aging management of some selected components (e.g., a reactor coolant pump casing might be managed within the In-service Inspection AMP, or within a component specific AMP for Reactor Coolant Pumps). All IGALL AMPs can be found in the periodically updated database.
The IGALL has defined the following nine attributes of an effective AMP and it is recommended that all AMPs address these attributes:
- Scope of the AMP based on understanding aging
- Preventive actions to minimize and control aging effects
- Detection of aging effects
- Monitoring and trending of aging effects
- Mitigation of aging effects
- Acceptance criteria
- Corrective actions
- Operating experience feedback and feedback of research and development results
- Quality management
Both the GALL and the IGALL reports define criteria for an effective AMP. Some differences in how these attributes are organized are as follows:
- While the GALL report outlines 10 attributes/elements for an effective AMP, the IGALL has established only 9.
- Attributes 8 (Confirmation process) and 9 (Administrative controls) from GALL report are covered by the attribute 9 from the IGALL (Quality management).
- The GALL report defines attribute/element 3 (Parameters Monitored/Inspected) which is addressed in IGALL's attribute 3 on Detection of aging effects.
- The IGALL defines attribute 5 (Mitigation of Aging Effects),however, the GALL report addresses mitigative actions across multiple “elements”; depending on the specific AMP.
IGALL AMPs that are NOT included in GALL[edit]
The following table (current as of 9/5/24) provides an overview of IGALL AMPs that are not included in GALL report along with a brief description and some corresponding EPRI Guidance documents. The IGALL methodology includes active and passive components in the scope of aging management. Active components can be managed by IGALL AMPs or other appropriate tools. These components in their respected AMPs are marked in purple.
| AMP | IGALL | Brief AMP description | REF. EPRI | TITLE EPRI |
|---|---|---|---|---|
| Reactor Coolant Pump | AMP138 | The purpose of this AMP is to manage aging effects of loss of material due to wear, erosion, boric acid corrosion, general corrosion; cracking due to SCC or fatigue; and loss of fracture toughness due to thermal aging which can lead to the loss of intended function of reactor coolant pump components including its active components (e.g., rotating parts). The most adequate inspection and testing techniques to carry out are non-destructive methods such as visual examination, capillary test, dimensional control, ultrasonic examination, hardness measurements, He bubble test, pressure and tightness test. These inspections should be conducted periodically. | ||
| CANDU/PHWR Fuel Coolant Channels | AMP139 | The aim of this AMP, devoted to PHWRs, is to manage aging effects of movement or shifting due to sustained vibratory loading, change in material properties due to hydrogen/deuterium uptake, neutron irradiation embrittelement, thermal aging; increase in flow resistance due to fouling; cracking due to fatigue, flow-induced vibration and delayed hydride cracking; change in material properties due to irradiation-assisted deformation that can lead to the loss of intended function of fuel coolant channels components. The most adequate inspection and surveillance techniques to carry out are inspection of the full volume of the tube, inside diameter measurements, direct measurement of PT-CT annular gap and monitoring of many important parameters such as irradiation induced dimensional changes, PT wall thinning, location of annulus spacers, and more. The frequency of the inspection depends on its type. | ||
| CANDU/PHWR Feeder Piping | AMP140 | This AMP, devoted to PHWRs, is focused on management of aging effects of cumulative fatigue damage due to fatigue; increase in flow resistance due to fouling; loss of fracture toughness due to dynamic strain or thermal aging; cracking due to SCC; loss of material due to general corrosion, fretting, wear and wall thinning due to preferential weld attack that can lead to the loss of intended function of feeder piping in the primary heat transport system. The most adequate inspection and monitoring techniques to carry out to detect degradations mechanisms in feeders are NDEs, ultrasonic testing to measure remaining wall thickness, visual inspections and superficial techniques like liquid penetrant test, or magnetic particle test. These inspections should be conducted periodically. | 1009561 | Materials Reliability Program: Generic Guidance for Alloy 600 Management (MRP-126) |
| CANDU/PHWR Reactor Assembly | AMP141 | The purpose of this AMP, devoted to PHWRs, is to manage aging effects of loss of material due to cracking, erosion, general corrosion, flow-accelerated corrosion, crevice corrosion; cracking due to SCC, fatigue, flow-induced vibration; loss of fracture toughness due to neutron irradiation embrittlement; loss of leak tightness due to stress relaxation and loss of strength due to elastomer degradation that can lead to the loss of intended function of critical reactor assembly components. The most adequate inspection and techniques to carry out are visual and ultrasonic NDEs, gap measurements between PTs, gap measurements between CTs, measurements of the guide tube, and more addressed in the AMP. Many of these inspections can be conducted only during refurbishment and large scale fuel channel replacement outage after approximately 25-30 years of operation. | ||
| CANDU/PHWR Fuel Handling | AMP142 | The aim of this AMP, devoted to PHWRs, is to manage aging effects of loss of material due to wear, erosion, corrosion; loss of fracture toughness due to neutron irradiation embrittlement; change in dimensions due to creep; cracking due to fatigue; loss of preload due to strees relaxation; and loss of toughness due to radiation damage. Those effects can lead to the loss of intended function of fuel handling systems of PHWR. The most adequate inspection techniques to carry out are visual inspections, and manual or physical manipulation of the material. These inspections should be conducted periodically. | ||
| Safety-related Valves | AMP143 | This AMP, devoted to PHWRs, is focused on management of aging effects of loss of material due to erosion, wear, general corrosion, flow accelerated, pitting and crevice corrosion; wall thinning due to corrosion, erosion; cracking due to fatigue, hardening and loss of strength due to elastomer degradation that can lead to the loss of intended function of important to safety valves such as motor operated valves, air operated valves, solenoid operated valves, manual valves, check valves, pressure relief valves including their active parts (e.g., actuator). The most adequate inspection and testing techniques to carry out are pressure test, leak tightness test and nondestructive testing methods such as visual tests, dimension tests, screw joint tightening tests and liquid penetrant test. These inspections should be conducted periodically. | ||
| Safety-related Pumps | AMP144 | The purpose of this AMP is to manage aging effects of loss of material due to erosion, wear, flow accelerated and general corrosion; cracking due to fatigue, SCC; wall thinning due to cavitation, corrosion and erosion that can lead to the loss of intended function of important to safety pumps such as centrifugal and positive displacement pumps, centrifugal horizontal-vertical pumps including their active parts (e.g., impeller). The most adequate inspection and testing techniques to carry out are nondestructive methods such as visual examination, ultrasonic examination, capillary test, or dimensional control. These inspections should be conducted periodically. | TR-107252 | Centrifugal and Positive Displacement Charging Pump Maintenance Guide |
| CANDU/PHWR Moderator and Moderator Purification Heat Exchangers | AMP145 | The aim of this AMP, devoted to PHWRs, is to manage aging effects of loss of material due to erosion, crevice corrosion, general corrosion, pitting, MIC, fretting; cracking due to SCC; cumulative fatigue damage due to fatigue and reduction in heat transfer due to fouling that can lead to the loss of intended function of heat exchangers of shell-and-tube type used in moderator system and moderator purification in PHWR. The most adequate inspection techniques to carry out are NDEs, visual, dimensional, surface and volumetric inspections; additionally leak testing of heat exchangers can be performed. The frequency of inspections is adjusted based on the results of degradation detected and in accordance with national regulations or governing documents. | 1018089 | Nuclear Maintenance Applications Center: Heat Exchanger Maintenance Guide |
| PMBD | Preventive Maintenance Basis, Volume 32: Heat Exchangers – Tube Type | |||
| 1003320 | Supplemental Guidance for Testing and Monitoring Service Water Heat Exchangers | |||
| 3002005340 | Service Water Heat Exchanger Testing Guidelines | |||
| NP-7552 | Heat Exchangers Performance Monitor Guidelines | |||
| CANDU/PHWR Inspection Programmes | AMP146 | This AMP, devoted to PHWRs, is focused on management of aging effects of loss of material due to wear, crevice corrosion, fouling, general corrosion, MIC, pitting; reduction in heat transfer due to fouling; cracking due to fatigue, PWSCC and SCC; increase in flow resistance due to fouling; loss of fracture toughness due to thermal aging; change in dimensions due to irradiation-induced creep; distortion due to swelling; wall thinning due to preferential weld attack; movement or shifting due to sustained vibratory loading that can lead to the loss of intended function of components of systems containing fluid that directly transports heat from nuclear fuel, systems essential for the safe shutdown, safe cooling system, or other systems whose failure could affect the integrity of the previously listed systems. The most adequate inspection techniques to carry out are NDEs such as visual, dimensional, surface and volumetric ones. Additionally, overall monitoring, leak detection, acoustic emission and strain measurement can be performed. These inspections should be conducted periodically. | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 |
| 3002000563 | Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R4) | |||
| Containment Bellows | AMP147 | The purpose of this AMP is to manage aging effects of cracking due to vibrational fatigue and SCC and cumulative fatigue damage due to fatigue, which can lead to the loss of intended function of containment bellows. The most adequate inspection techniques to carry out are nondestructive examinations such are visual and surface inspections, Additionally, leak rate tests may be performed. The frequency of the inspections and leak testing is determined by the service and environmental conditions involved, degradations detected, and in compliance with other requirements. | 1008035 | Expansion Joint Maintenance Guide |
| CANDU/PHWR Reactor Shutdown Systems | AMP148 | The aim of this AMP, devoted to PHWRs, is to manage aging effects of change in dimensions due to irradiation induced creep; cracking due to flow induced vibration and fatigue; loss of material due to wear, erosion, corrosion; distortion due to swelling; and loss of fracture toughness due to neutron irradiation embrittlement, These aging degradation mechanisms can lead to the loss of intended function of components of the reactor shutdown systems in PHWR. The most adequate inspection techniques to manage them are NDEs such as visual, dimensional, surface and volumetric inspections. Additionally, SDS-1 rod drop tests may be performed. These inspections should be conducted periodically. | ||
| CANDU/PHWR Heavy Water Management | AMP149 | This AMP, devoted to PHWRs, is focused on management of aging effects of loss of material due to corrosion that can lead to the loss of intended function of components of heavy water collection, supply, vapor and liquid recovery systems to minimize heavy water leakages and losses. This program is based mainly on online tritium monitoring and chemistry monitoring complemented by plant system periodic inspections and walkdowns. | ||
| CANDU/PHWR Annulus Gas System | AMP150 | In this AMP, the aging effects managed are loss of material due to corrosion or wear; loss of sealing function due to hardening; and cracking due to fatigue, which can lead to the loss of intended function of components of annulus gas system. This program is based mainly on monitoring of flow by each group of channels, dew point temperatures, concentrations of deuterium, oxygen and nitrogen and complemented by periodic maintenance of major components. | ||
| CANDU/PHWR Primary Heat Transport Instrument Tubing | AMP151 | The purpose of this AMP devoted to PHWRs is to manage aging effects of loss of material due to fretting or wear, and cracking due to SCC and they can lead to the loss of intended function of instrument line tubing and transmitter impulse line tubing that contain primary heat transport coolant. The most adequate inspection techniques to carry out are visual inspections. These inspections should be conducted periodically. | ||
| WWER Reactor Pressure Vessel Surveillance | AMP152 | The aim of this AMP, devoted to WWERs is to manage aging effects of loss of fracture toughness due to thermal aging and neutron irradiation embrittlement that can lead to the loss of intended function of reactor pressure vessel beltline. This AMP is a surveillance program based on surveillance of the representative limiting materials of the reactor pressure vessel by testing of irradiated capsules. | ||
| WWER Main Gate Valves | AMP153 | This AMP, devoted to WWERs, is focuses on management of aging effects of cracking due to SCC; loss of fracture toughness due to thermal aging; cumulative fatigue damage due to fatigue; loss of preload due to gasket creep, self-loosening, thermal effects and loss of material due to boric acid corrosion. These aging effects can lead to the loss of intended function of main gate valves including their active parts (e.g., actuator). The most adequate inspection and testing techniques to manage them are NDEs such as visual inspections, dimension control, ultrasonic inspection, and dye penetrant, pressure and tightness tests. These inspections should be conducted periodically. | ||
| PWR Pressurizer | AMP154 | In this AMP, the aging effects managed are loss of material due to boric acid corrosion; cracking due to fatigue and SCC, that can lead to the loss of intended function of components of pressurizer. The most adequate inspection and testing techniques to carry out are nondestructive methods such as visual examination, capillary test, dimensional control and ultrasonic examination. These inspections should be conducted periodically. | ||
| PWR Residual Heat Removal Heat Exchangers | AMP155 | The purpose of this AMP is to manage aging effects of loss of preload due to stress relaxation; cracking due to SCC and fatigue; loss of material due to crevice corrosion, erosion, general corrosion, fretting, wear; reduction in heat transfer due to fouling that can lead to the loss of intended function of shell-and-U-tube heat exchangers of residual heat removal system. The most adequate inspection techniques to carry out are NDEs such as visual, dimensional, surface and volumetric inspections; additionally, leak-testing can be performed. These inspections should be conducted periodically. | 1018089 | Nuclear Maintenance Applications Center: Heat Exchanger Maintenance Guide |
| PMBD | Preventive Maintenance Basis, Volume 32: Heat exchangers Condition Assessment Program | |||
| NP-7552 | Heat Exchanger Performance Monitoring Guidelines | |||
| PWR Main Coolant Piping | AMP156 | The aim of this AMP is to manage aging effects of loss of fracture toughness due to thermal aging, cracking due to SCC, cumulative fatigue damage due to fatigue. Those can lead to the loss of intended function of main coolant piping. The most adequate inspection techniques to carry out are visual, dye penetrant, ultrasonic inspections and magnetic particle method. These inspections should be conducted periodically. | ||
| Passive Hydrogen Recombiiners | AMP158 | The objetive of this AMP is to address the aging effects of loss of material due to general corrosion, pitting corrosion or wear, and reduction of hydrogen recombining capacity due to fouling. Those can lead to the loss of intended function of hydrogen recombiners. Periodic functional test and visual inspection are performed to detect the mentioned aging effects. | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 |
| PWR Emergency Core Cooling System Hydro-accumulators | AMP159 | This AMP is focused on management of aging effects of loss of material due to pitting, crevice, general and boric acid corrosion and those can lead to the loss of intended function of components of emergency core cooling system hydro-accumulators. The most adequate inspection and testing techniques to carry out are visual, dimensional control, ultrasonic inspections and penetration tests to detect surface cracks. These inspections should be conducted periodically. | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 |
| PWR Reactor Pressure Vessel | AMP162 | In this AMP, the aging effects managed are loss of fracture toughness due to thermal aging and neutron irradiation embrittlement; loss of material due to boric acid, wear, crevice and pitting corrosion; cracking due to fatigue and SCC; cumulative fatigue damage due to fatigue; crack growth due to cyclic loading. Those can lead to the loss of intended function of reactor vessel, flange joint, upper and bottom heads and RPV control rod drive mechanism and bottom-mounted instrumentation nozzles. The most adequate inspection techniques to manage them are visual inspection, dye penetrant, magnetic particle, eddy current, or ultrasonic testing. These inspections should be conducted periodically. | 3002016009 | Materials Reliability Program: Effects of Thermal Ageing on Reactor Coolant System Pressure Boundary Materials (MRP-438), Low Alloy Ferritic Steels |
| 3002017168 | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227, Revision 1-A) | |||
| Dissimilar Metal Welds | AMP163 | The purpose of this AMP is to manage aging effects of loss of material due to boric acid corrosion; cracking due to SCC or fatigue; cumulative fatigue damage due to fatigue; and loss of fracture toughness due to thermal aging. Those can lead to the loss of intended function of dissimilar welds. The most adequate inspection techniques to carry out are visual, dye penetrant, eddy current, or volumetric ultrasonic testing. These inspections should be conducted periodically. | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 |
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 1012621 | BWRVIP-75-A: BWR Vessel and Internals Project, Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules | |||
| 1015009 | MRP-139 Revision 1: Primary System Piping Butt Welds Inspection and Evaluation Guideline | |||
| 1006603 | Materials Reliability Program: GE Experience Report on Cracking in Alloy 182 (MRP-57): BWR Alloy 182 Stress Corrosion Cracking | |||
| 1003523 | Materials Reliability Program: A Review of Thermal Aging Embrittlement in Pressurized Water Reactors (MRP-80) | |||
| 1021023 | Materials Reliability Program: Primary Water Stress Corrosion Cracking (PWSCC) Flaw Evaluation Guidance (MRP-287) | |||
| 3002012244 | Nondestructive Evaluation: Guideline for Conducting Ultrasonic Examinations of Dissimilar Metal Welds, Revision 3 | |||
| 1015400 | Materials Reliability Program: Advanced FEA Evaluation of Growth of Postulated Circumferential PWSCC Flaws in Pressurizer Nozzle Dissimilar Metal Welds (MRP-216, Rev. 1) | |||
| 1009378 | Materials Reliability Program: Welding Residual and Operating Stresses in PWR Alloy 182 Butt Welds (MRP-106) | |||
| 1009549 | Materials Reliability Program: Alloy 82/182 Pipe Butt Weld Safety Assessment for U.S. PWR Plant Designs (MRP-113) | |||
| 1009559 | Materials Reliability Program: Evaluation of the Effect of Weld Repairs on Dissimilar Metal Butt Welds (MRP-114) | |||
| 1009805 | Materials Reliability Program: Alloy 82/182 Pipe Butt Weld Safety Assessment for US PWR Plant Designs: Babcock & Wilcox Design Plants (MRP-112) | |||
| 1006696 | Materials Reliability Program: Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82, 182, and 132 Welds (MRP-115) | |||
| 1009806 | Materials Reliability Program: Probabilistic Risk Assessment of Alloy 82/182 Piping Butt Welds (MRP-116) | |||
| Outdoor Piping, Tanks and Structures | AMP164 | The aim of this AMP is to manage aging effects of loss of material due to fouling, wear, crevice, general, MIC, pitting corrosion; loss of preload due to self-loosening, gasket creep, thermal effects; and cracking due to SCC. These aging effects can lead to the loss of intended function of ferrous and non-ferrous alloy above ground outdoor piping, tanks, structures and their supports. The most adequate inspection techniques to identify and manage them are volumetric examination methods, physical measurements for detecting changes in dimension, ultrasonic testing and visual examinations. These inspections should be conducted periodically. | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Essential Chillers | AMP165 | This AMP is focused on management of the aging effects of mechanical parts of centrifugal essential chillers used in NPPs. The management of ageing of electrical and electronic devices of essential chillers is addressed in AMP212, AMP215, AMP217, AMP218 and TLAA201. The aging effects managed are cracking due to fatigue; loss of material due to corrosion and wear; loss of sealing function due to hardening; bearing failure and fatigue due to excessive vibration; reduced heat transfer capability and differential pressure increase due to fouling; increase in flow resistance due to fouling due to corrosion and wear which will lead to reduced cooling capbility, their intended function. This AMP includes preventive actions based on chemical and vibration monitoring and tube cleaning. The most adequate inspection and testing techniques to carry out are external and internal visual inspections and eddy current testing. In addition, operator rounds and systems performance are used too. These inspections should be conducted periodically. | 1015075 | Plant Support Engineering: Life Cycle Management Planning Sourcebooks - Chillers |
| Dry Storage Cask System | AMP166 | The aim of this AMP is to manage aging effects of loss of material due to general, pitting, crevice corrosion; cracking due to SCC. These aging effects can lead to the loss of intended function of metallic components of a dry cask storage systems of various designs in dry storage facilities. The most adequate inspection techniques to identify and manage them are visual inspections, surface and volumetric examinations. For sites conducting a canister examination, there is usually a minimum of one canister examined at each site. Preference is usually given to the canisters with the greatest susceptibility for localized corrosion or SCC. Remote visual examinations of outer surfaces are performed for all accessible dry storage casks. These inspections should be conducted periodically. | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 |
| Oil-Immersed Power Transformers Not Subject to Equipment Qualification Requirements | AMP211 | The described AMP211 aims to ensure the intended safety functions of non-grid connected plant distribution oil-cooled transformers throughout the end of service life. It focuses on monitoring components subject to age-related thermal degradation resulting in reduced insulation resistance, or increased resistance of connection due to corrosion or loosening, or loss of sealing. The AMP implements preventive actions and detection methods, including periodic visual inspections, dissolved gas analysis, periodic electrical testing and monitoring and trending of winding and oil temperatures. | 1016301 | Power Transformer Guidebook: The "Copper Book" |
| 1013566 | Plant Support Engineering: Large Transformer End-of-Expected-Life Considerations and the Need for Planning | |||
| 1025261 | Plant Engineering: Medium-Voltage Transformer End of Expected Life Guidance | |||
| 3002000753 | On-Line Monitoring Diagnostic Analysis for Large Power Transformers | |||
| Electrical Enclosures Not Subject to Equipment Qualification Requirements | AMP212 | This AMP is focused on management the age-related degradation effects such as loss of material, loss of preload, and loss of sealing functions on electrical enclosures. The program entails visual inspections of both internal and external surfaces, with the inspection frequency determined by the type of electrical enclosure and operational experience. Visual inspections cover 100 percent of accessible component surfaces. Manual or physical manipulation of at least 10 percent of the available surface area can be used to enhance visual inspection, ensuring the absence of hardening or loss of strength in elastomers and flexible polymeric materials. Preventive measures include maintaining specified environmental conditions. | 1007933 | Aging Assessment Field Guide |
| 1009743 | Aging Identification and Assessment Checklist: Mechanical Components | |||
| Whiskers and Capacitors with Liquid Electrolyte | AMP213 | The described AMP213 focuses on periodic inspections to identify aging effects in electronic and electrical equipment caused by whiskers and degradation of capacitors with liquid electrolyte. Whiskers can only be detected through regular visual inspections using a microscope with at least 10 times magnification and suitable lighting. Aging progress of capacitors is monitored by periodic measurement of residual capacity or direct capacitance measurement. Under certain construction circumstances, the equivalent series resistance of capacitors may also be periodically measured. Generally, after 7-9 years of operation, these measurements are recommended annually. If measurements are not feasible, replacement every 9 to 15 years is probably the only solution to address aging process. | 1008166 | Guidelines for the Monitoring of Aging of I&C Electronic Components |
| Electrical Insulation of Rotating Electrical Machines and Actuators Not Subject to Equipment Qualification Requirements | AMP214 | This AMP aims to ensure that the insulation function of rotating electrical machine and actuators components remains consistent with the current licensing basis throughout their operational lifetime. Degradation mechanisms such us reduced insulation resistance and loss of dielectric strength, can weaken insulation materials. The program involves periodic visual inspections to detect surface anomalies in insulation materials. Insulation diagnosis for a component is done regularly. For medium voltage components, it confirms no major change in insulation characteristics, involving electrical and mechanical diagnosis. Electrical diagnosis may cover insulation resistance, polarization index, dielectric strength, alternating current, tan delta, and partial discharge testing. | 1014908 | Guide for Rotating Machine Stator Winding Hipot Testing |
| 3002016077 | Medium-Voltage Motor and Cable, Very-Low-Frequency (VLF) Tan Delta Testing from the Cable Termination: VLF Motor and Cable Testing | |||
| 1007423 | Life Cycle Management Planning Sourcebooks, Volume 5: Main Generator | |||
| 1003095 | Electric Motor Tiered Maintenance Program | |||
| Switchgears, Breakers, Distribution Panels, Contactors, Protection Relays, Relays Not Subject to Equipment Qualification Requirements | AMP215 | The AMP215 is focused on identify age-related degradation in indoor low and medium voltage switchgears and active components (e.g., protection relay) typically found in switchgear cabinets. The aging effects that this AMP manage are increase in resistance of connection, loss of electrical function, loss of material, loss of mechanical function, reduction of insulation, characteristic change, contact sticking and increase in friction. Periodic visual inspections, including cleaning and thermography, are conducted to ensure the proper functioning of components. Thermography is utilized to detect high-resistance connections or abnormal heating patterns across all accessible components and connections. Airborne acoustic testing may be employed in medium voltage switchgear to identify discharges. Preventive maintenance on breakers is carried out periodically according to manufacturer recommendations, and functional tests are performed on breakers and protection relays based on the same guidelines. Surveillance testing is conducted to assess the safety functions of switchgear and its components. | 1007933 | Aging Assessment Field Guide |
| 1013457 | Nuclear Maintenance Applications Center: Switchgear and Bus Maintenance Guide | |||
| 1011223 | Aging Identification and Assessment Checklist: Electrical Components | |||
| Lead Batteries Not Subject to Environmental Qualification Requirements | AMP216 | This AMP outlines an aging management program for wet cell lead batteries used in standby operation, parallel to rectifier units, within nuclear power plants. The program focuses on visual inspections, surveillance tests, and monitoring of battery voltage, current, and room temperature to detect aging effects resulting in decreased capacity due to corrosion or chemical processes as well as leakage due tp cracking. Periodic testing, including capacity tests, is conducted out every 1-5 years. | ||
| Sensors and Transmitters Not Subject to Equipment Qualification Requirements | AMP217 | The described AMP217 is a condition monitoring program for I&C sensors and transmitters crucial for safety functions but not part of the Environmental Qualification (EQ) program in NPPs. Preventive actions are limited to periodic replacement of consumables, and detection of aging effects, such as characteristic change, degradation of electronic components, loss of sealing function, loss of vibration alarm or indication, loss of winding temperature indication, and reduction in insulation, are managed carrying out techniques like calibration, component installation verification, visual inspection, and response time testing. The program includes periodic visual inspection as part of periodical walkdowns of each system or during routine maintenance tasks, periodic calibration determined and venturi fouling observation by trending independent plan parameters. | 1008166 | Guidelines for the Monitoring of Aging of I&C Electronic Components |
| 1003568 | Collected Field Data on Electronic Part Failures and Aging in Nuclear Power Plant Instrumentation and Control (I&C) Systems | |||
| NP-7121 | Technical Guidance for Detection of Oil-Loss Failure of Rosemount Pressure Transmitters | |||
| 1021429 | Nuclear Maintenance Applications Center: Guidelines for the Maintenance Management of Plant Sensors | |||
| TR-100514-V2 | Survey and Characterization of Feedwater Venturi Fouling at Nuclear Power Plants: Volume 2: Photomicrograph and Chemical Analyses | |||
| Electronic Equipment Not Subject to Equipment Qualification Requirements | AMP218 | This AMP outlines a program to maintain electronic equipment installed in I&C systems with respect to IEC 62342, focusing on mitigating environmental conditions, detecting failure mechanisms, and predicting end-of-life for critical components. It addresses preventing generic failure mechanisms from affecting safety and managing limitations due to obsolescence and physical aging. The program includes tasks for the establishment of an aging data base such as identifying critical components, conducting functional tests, failure analysis, evaluating residual lifetime, environmental monitoring, and performing visual inspections. Aging effects such as characteristic change, degradation of electronic components, increase in resistance of connection, loss of electrical function and reduction in insulation resistance are detected through periodic visual inspections, and in-situ testing or periodic electrical measurements. Environmental conditions are measured and tracked during a mid/long-term period. Periodic electric measurements and visual inspections are implemented to identify electronic components experiencing failures, which are then documented in a database. | 1008166 | Guidelines for the Monitoring of Aging of I&C Electronic Components |
| 1011709 | Evaluating the Effects of Aging on Electronic Instrument and Control Circuit Boards and Components in Nuclear Power Plants | |||
| 1003568 | Collected Field Data on Electronic Part Failures and Aging in Nuclear Power Plant Instrumentation and Control (I&C) Systems | |||
| 1022246 | Guidance for Aging Management of Instrumentation and Control (I&C) Circuit Cards and Components Based on Electricite de France (EDF)Experience | |||
| Fuses Not Subject to Equipment Qualification Requirements | AMP219 | The AMP219 is focused on managing the aging effects of fuses installed to ensure their intended functions are maintained throughout their operational lifetime. It addresses aging effects such as characteristic change or loss of electrical function due to due to electrical transients, elevated temperature or thermal cycling. Periodic resistance testing during manufacturing ensures fuse acceptability. Aged fuse populations undergo cycling tests within national regulations, verifying they don't open unexpectedly. Following cycling, an overcurrent test confirms proper fuse response. Testing applies to a representative sample designated by the NPP; extensions occur if negative OPEX is found. Failure rates are monitored to identify the most common fuse failures. Fuses operated at under 60% of their rated current may have an indefinite lifetime, a factor to consider when selecting fuses. | ||
| Lightning Protection, Grounding Grid and Surge Arresters Not Subject to Equipment Qualification Requirements | AMP220 | The purpose of this AMP is to manage aging effects of cracking, loss of material properties due to surge or voltage spike; increase in resistance of connection due to corrosion, surge, or voltage spike; loss of electrical function due to corrosion, fatigue which can lead to the loss of intended function of lightning protection, grounding systems, and medium voltage and high voltage surge arresters. The most adequate inspection techniques to carry out are low ohmic resistance measurements of all connections attached to the protective equipotential bonding, control of earth-termination system, visual inspections of all accessible parts of lightning protection and grounding systems. Medium voltage and high voltage arresters can be inspected by non-invasive thermographic surveys and visual inspections of accessible parts. These inspections should be performed periodically. Inspections should be complemented by online monitoring of selected paramaters, such as leakage currents to ground. | 1013457 | Nuclear Maintenance Applications Center: Switchgear and Bus Maintenance Guide |
| 3002018920 | Surge Arresters—Mechanical and Aging Testing | |||
| 1026664 | Nuclear Maintenance Applications Center: Switchyard Equipment Application and Maintenance Guide | |||
| Fiber Optic Cables and Connections not Subject to Equipment Qualification Requirements | AMP222 | AMP222 focuses on ensuring the proper functioning of fiber optic cables and connections exposed to adverse localized environments (high temperature, radiation, moisture, wear, and chemicals) without environmental qualification requirements. The program implements condition monitoring to detect aging effects, such as loss of signal, loss of mechanical properties, loose connection, increased signal time dispersion, increased attenuation, hardening or loss of strength and decrease in optical power transmission. The program includes periodic visual inspections and signal transmission performance evaluations. | ||
| Electrical Insulation for Medium Voltage Shielded Cables and Connections Not Subject to Equipment Qualification Requirements | AMP223 | The AMP223 focuses on effectively managing aging effects on the electrical insulation of medium voltage shielded cables and connections exposed to adverse localized environments (temperature, radiation, significant moisture, wear, and or chemical). Preventive measures include maintaining thermal insulation (accessible cables) and periodic drainage of accumulated water (inaccessible cables). Through detection and monitoring techniques such as periodic visual inspections, infrared thermography or tan testing, the program aims to prevent premature failures in medium voltage cable circuits due to cracking, discoloration, elastomer degradation, embrittlement, hardening or loss of strength, loss of dielectric, loss of mechanical properties, reduction in insulation resistance or swelling. For cables in service, testing is recommended before the first failure or after 15-20 years of service. Subsequent tests occur every 6-10 years, with no 25% grace period allowed for longer intervals. All cables under the aging management program are tested at least once before extended operation, and then every 6-10 years thereafter. | TR-109619 | Guideline for the Management of Adverse Localized Equipment |
| 1021070 | Medium Voltage Cable Aging Management Guide, Revision 1 | |||
| 3002000557 | Plant Engineering, Aging Management Program Guidance for Medium-Voltage Cable Systems for Nuclear Power Plants, Revision 1 | |||
| 1024044 | Aging Power Cable Maintenance Guideline | |||
| 1022969 | Plant Engineering: Electrical Cable Test Applicability Matrix for Nuclear Power Plants | |||
| 3002000576 | Long-Term Operations Program: Assessment of Research and Development Supporting Aging Management Programs for Long-Term Operation | |||
| 1022968 | Plant Engineering: Cable Aging Management Program Implementation Guidance | |||
| 1008560 | Equipment Failure Model and Data for Underground Distribution Cables: A PM Basis Application | |||
| 1011873 | Cable Polymer Aging and Condition Monitoring Research at Sandia National Laboratories Under the Nuclear Energy Plant Optimization (NEPO) Program | |||
| Electrical Motors not Subject to Equipment Qualification | AMP224 | The AMP 224 addresses the aging of motors in NPPs, its subcomponents and support structures, focusing on both large and small motors. It recognizes the environmental stressors faced by these motors, including radiation, temperature, humidity, and vibration. The aging effects this AMP manages are bearing failures, increased heating in stator core, loss of insulation or reduced insulation resistance, loss of vibration alar or indication, loss of winding temperature indication, motor failure, rotor heating, and stator heating. Different strategies for detecting aging effects are provided, such as comparative surge tests, motor circuit analysis, internal visual inspection, visual or borescope inspection, vibration monitoring, bearing temperature monitoring, periodic checks of lube oil system parameters, polarization index checks, and motor circuit analysis. | NP-7502 | Electric Motor Predictive and Preventive Maintenance Guide |
| Fans Used in I&C and Power Electronics Cabinets | AMP226 | AMP226 outlines that fans used in Instrumentation and Control (I&C) or power electronics cabinets intended functions are maintained in line with the CLB throughout their operational lifetime. Fans exposed to indoor controlled air are susceptible to calibration drift, degradation of electronic components, loss of mechanical function, polymer degradation or winding/coil failure. As a basic preventive measure, normal environmental condition is respected, and cabinet’s air filters are cleaned or replaced periodically. Periodic visual inspections and surveillance tests are regularly conducted to detect potential anomalies. | PMBD | EPRI Preventive Maintenance Basis Database (PMBD), Inverter template |
| Low-Voltage Coils of Control Rod Drive System Not Subject to Equipment Qualification Requirements | AMP227 | The purpose of this AMP is to manage aging effects of reduced insulation resistance due to thermal degradation of organic material, embrittlement, degradation caused by ohmic heating; coil failure due to fatigue of conductor material that can lead to the loss of intended function of low voltage coils of control rod drive system. This AMP is based on condition monitoring of electrical properties such as insulation resistance measurement and measurement of coil resistance. | ||
| Capacitor Voltage Transformer Not Subject to Equipment Qualification Requirements | AMP228 | The aim of this AMP is to manage aging effects of loss of dielectric strength due to ohmic heating, moisture intrusion; reduced insulation resistance due to ohmic heating and thermal degradation of organic materials; loss of sealing function due to moisture intrusion, erosion; winding/coil failure due to ohmic heating. These aging effects can lead to the loss of intended function of capacitor voltage transformers. The most adequate techniques to identify and manage them is monitoring of selected parameters. For some electrical parts of the capacitor voltage transformers, an oil and dissolve gas analysis shall be performed. | ||
| Power Transformer Tap-Changers Not Subject To Equipment Qualification Requirements | AMP229 | AMP229 focuses on ensuring the proper functions of on-load tap-changers (OLTC) associated with oil-immersed transformers. This AMP covers OLTCs found on oil-immersed transformers e.g. generator transformers, auxiliary power transformers, or standby auxiliary power transformers. The aging effects managed are loss of mechanical function due to overload or wear of pivots and linkages; loss of electrical function due to ohmic heating or abrasion of contacts; loss of dielectric stenght due to moisture or chemical degradation of oil, or due to presence of moisture or suface contamination. This AMP focuses on the demands for the inspections and the surveillance test programme which should be conducted periodically. In addition, routine oil sample checks are also applicable to the OLTCs as well as infrared thermography of the diverter and selector compartments. | 1012350 | New Equipment and Performance Design Review - LTC Management Course Materials |
| 1002048 | Development of a Filter Using Absorbent Technologies for the Removal of Coking Precursors: Laboratory Evaluation | |||
| 1011708 | Development of a New Acoustic Emissions Technique for the Detection and Location of Gassing Sources in Power Transformers and LTCs: Phase 2 Results | |||
| 1016261 | Load Tap Changer Management Seminar | |||
| 1001946 | Development of Load Tap Changer Monitoring Technique: Mechanism of Coking | |||
| Generators for Emergency Diesel Generator Systems not Subject to Equipment Qualification Requirements | AMP230 | The aim of this AMP is to manage aging effects of bearing failures due to mechanical vibration, loss of lubrication, surface contamination or chemical contamination; loss of mechanical function due to fatigue, vibration, surface contamination, elevated temperature, moisture intrusion, corrosion, overload; rotor heating due to thermal degradation of organic materials or mechanical vibration; reduced insulation resistance and/or loss of dielectric strength due to thermal degradation of organic materials, moisture and debris intrusion, surface contaminants. These agings effects can lead to the loss of intended function of generators of emergency diesel generators. The most adequate techniques to identify and manage them are vibration and parameter monitoring, thermography, electrical tests, visual inspections, or borescope inspections. These inspections should be conducted periodically. | 3002005014 | Generator Maintenance Guide for Emergency Diesel Generators |
| 3002005014 | Generator Maintenance Guide for Emergency Diesel Generators | |||
| 3002000742 | On-Line Monitoring of Emergency Diesel Generators | |||
| Isolated Phase Bus Not Subject To Equipment Qualification Requirements | AMP231 | The purpose of this AMP is to manage internal and external aging effects of isolated phase bus components. The aging effects managed are hardening, loss of strength due to moisture intrusion, surface contamination or thermal degradation of organic materials; loss of sealing due to moisture intrusion; loss of material due to corrosion; reduced insulation resistance and/or dielectric strength due to moisture and debris intrusion, surface contamination, thermal degradation of organic materials; loss of mechanical function due to thermal fatigue or vibrational fatigue; increased resistance due to loosening of bolted connections, significant ohmic heating, electrical transients, vibration, contamination, corrosion or oxidation; cracking due to fatigue; and loss of electrical function due to electrical transients or thermal cycling. The most adequate inspection and testing techniques to carry out are visual inspection, thermographic inspections, ultrasonics and electrical test. These inspections should be conducted periodically. | 1015057 | Nuclear Maintenance Applications Center: Isolated Phase Bus Maintenance Guide |
| 3002026348 | Guideline for System Monitoring by System Engineers | |||
| 3002012582 | Infrared Thermography Guide | |||
| 1013457 | Nuclear Maintenance Applications Center: Switchgear and Bus Maintenance Guide | |||
| Non-metallic Liner | AMP309 | This AMP is focused on management of aging effects of damage due to irradiation, loss of sealing function due to abrasions, adhesion loss, blister, burns, cracks, cuts, delamination, tears; premature local failure due to irradiation, reduction in leak tightness due to irradiation and chemical evolution of the product with time that can lead to the loss of intended function of non-metallic liners of concrete containment structures. The most adequate inspection and testing techniques to carry out are visual inspection and leak rate test. These inspections should be conducted periodically. | ||
| Ground Movement due to Expansive Soils | AMP310 | In this AMP, the aging effects managed are cracking and distortion due to increase in stress levels from settlement; reduction of strength and mechanical properties of concrete due to irradiation; cracking due to differential settlement, erosion of porous concrete; reduction in foundation strength due to differential settlement, erosion of porous concrete sub-foundation; increase in porosity and permeability due to leaching of calcium hydroxide; and tilt mechanism due to differential settlement or heave effect from expansive soil. These effects can lead to the loss of intended function of all structures and components included in the scope of AMP302, AMP305, AMP307, AMP318 and AMP319. This AMP is based on monitoring of the ground movements by, for example, topographic leveling gauges, or extensometers embedded deep into the ground. | ||
| Containment Monitoring System | AMP311 | The purpose of this AMP is to manage aging effects of failure of monitoring in concrete structure due to corrosion, component rupture or excess concrete strain, lack of electrical continuity, mechanical dislocation; and loss of prestress due to creep, elevated temperature, relaxation, shrinkage. Those can lead to the loss of intended function of monitoring system components installed in concrete structure. This AMP is based on periodic testing of vibrating wire strain gauges. The electrical systems dedicated to concrete strain and temperature are continuously monitored. In case of pendulums and invar wires, an inspection in accessible areas is suggested. | 3002007819 | Program on Technology Innovation: Retrofitted Sensors for Nuclear Containment Structures |
| Concrete Expansion Detection and Monitoring System | AMP312 | This AMP is focused on management of aging effects of cracking due to aggressive chemical attack and corrosion of embedded steel and distortion due to increase in stress levels from settlement; increase in porosity and permeability due to aggressive chemical attack; loss of material due to aggressive chemical attack and corrosion of embedded steel; building deformation due to alkali-aggregate reaction or delayed ettringite formation; concrete expansion and cracking due to alkali-aggregate reaction or delayed ettringite formation; cracking and distortion due to increase in stress levels from settlement; loss of bond due to corrosion of embedded steel; reduction in concrete anchor capacity due to local concrete degradation, service-induced cracking or other concrete degradation mechanisms. These effects can lead to the loss of intended function of all concrete structures that are initially inspected in accordance with AMP302, AMP307 and AMP318, and determined to have cracking patterns that may indicate the presence of alkali aggregate reaction or delayed enttringite formation. The most adequate inspection techniques to carry out are visual inspections and expansion monitoring based on strain measurements. | 3002005389 | Tools for Early Detection of ASR in Concrete Structures |
| 3002007806 | Concrete Nondestructive Evaluation for Damage Due to Pattern Cracking - Alkali Silica Reaction and Freeze-Thaw Damage | |||
| 3002016056 | Long-Term Operations: Aging Management of Concrete Structures Affected by Alkali-Silica Reaction | |||
| 3002010300 | Mitigation and Repair of Concrete Structures Affected by Alkali-Silica Reaction (ASR) | |||
| Containment Prestressing System | AMP313 | In this AMP, the aging effects managed are loss of prestress due to creep, elevated temperature, relaxation, shrinkage; loss of strength due to creep shrinkage; and loss of material due to corrosion. Those can lead to the loss of intended function of components of prestressing system of prestressed concrete containments. The most adequate periodic testing techniques to carry out are lift-off tests, measurements of strains, displacements of the containment structure measured during periodic containment pressure tests. The parameters monitored are the containment tendon pre-stressing forces in accordance with AMP302. | ||
| Seismic Isolation | AMP314 | The purpose of this AMP is to manage aging effects of delamination of the elastomer from the reinforcing steel plate due to cracking of polymer material or loss of adhesion from steel plate; increase in rigidity of aseismic bearing supports due to polymer aging; loss of material due to cracking, crumbling and erosion of polymer; and loss of material due to corrosion of steel plates of aseismic bearing. Those effects can lead to the loss of intended function of aseismic bearings. The most adequate inspection techniques to carry out are visual inspections complemented by mechanical tests on representative samples. These inspections should be conducted periodically. | ||
| Spent Fuel Pool | AMP315 | This AMP is focused on management of aging effects of cracking due to fatigue or SCC; loss of material due to crevice, general, pitting corrosion, or defects of material surface layer due to chemical attack; and welding imperfection propagation due to thermal cyclic loading. Those can lead to the loss of intended function of spent fuel and fuel handling pools with stainless steel liners. The most adequate inspection techniques to carry out are visual inspection of accessible parts, remote visual inspections. Leak tightness can be monitored by data obtained from leakage collection systems. These inspections should be conducted periodically. | ||
| Subsurface Engineered Backfill Materials | AMP316 | In this AMP, the aging effects managed are changes in mechanical properties due to chemical degradation, dynamic loads and other phenomena; and changes in chemical properties due to chemical degradation, leaching and other phenomena of subsurface engineered backfill material, which can lead to the loss of intended function of embedded structures. The AMP consists of periodic in-situ tests on engineered backfill in which the foundations of nuclear safety related structures are embedded. In-situ tests are supplemented by conducting mechanical tests and visual inspections on representative samples. | ||
| Settlement of Structures | AMP317 | The purpose of this AMP is to manage aging effects of cracking of concrete structures due to displacement of the settlement that can lead to the loss of intended function of civil structures from groups 1 to 9, containment structures and their component supports. The most adequate testing techniques are tests carried out on sands, clays, rocks. Moreover, visual inspections within cracking monitoring program can verify whether the cracks in concrete structures are active or passive. | 1015078 | Plant Support Engineering: Aging Effects for Structures and Structural Components (Structural Tools) |
| Vibration and Cyclic Loading on Civil Structures | AMP320 | The aim of this AMP is to manage aging effects of cracking due to cyclic loading, cracking, cumulative fatigue damage, loss of leak tightness, loss of material properties and plate bulging, that can lead to the loss of intended function of concrete and non-concrete structures, structural components, component supports, and structural commodities subjected to vibration and cyclic loads. The most adequate periodic inspection, monitoring and surveillance techniques to carry out are visual inspections and monitoring of selected parameters. | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Monitoring of Concrete Structures During Delayed Construction | AMP321 | This is a plant specific AMP developed to ensure that the prolonged delays in the construction of an NPP do not result in irreversible or irreparable dagames of civil structures and civil components. The purpose of this AMP is to manage aging effects of cracking due to corrosion of embedded steel, differential settlement, erosion settlement, creep, freeze and thaw-frost action, aggressive chemical attack, shrinkage; expansion and cracking due to reaction with aggregate or delayed ettringite formation; loss of material due to corrosion of embedded steel, aggressive chemical attack; increase in porosity and permeability due to aggressive chemical attack; loss of strength due to leaching of calcium hydroxide and carbonation that can lead to the loss of intended function of concrete structures and masonry block walls, constructed completely or partially. The most adequate inspection techniques to carry out are periodic visual inspections. | 3002013084 | Long-Term Operations: Subsequent License Renewal Aging Effects for Structures and Structural Components (Structural Tools) |
| 3002007799 | Field Guide: Visual Inspection of Concrete Structures in the Nuclear Fleet | |||
| 1025627 | Program on Technology Innovation: Nondestructive Evaluation Inspection of Concrete Structures Subjected to Corrosion | |||
| 1023006 | Advanced Nuclear Technology: Embedded Sensors in Concrete | |||
| 3002007810(Archived) | Program on Technology Innovation: Assessment of Software Platforms for Aging Management of Large Civil Structures | |||
| 3002003090(Archived) | Corrosion Mitigation of Conventionally Reinforced Concrete Structures | |||
| Preservation of Non-Concrete Structures During Delayed Construction | AMP322 | The purpose of this AMP is to manage aging effects of cracking due to SCC; loss of material due to general, galvanic, crevice, pitting, MIC corrosion; and change in material properties due to ultraviolet radiation, ozone and thermal exposure, which can lead to the loss of intended function of non-concrete structures and components in a condition of delayed construction. This is a condition monitoring program that consists of monitoring of selected parameters by periodic visual inspections, supplemented as needed by nondestructive tests and other methods. | 1025323 | Field Guide: Coatings Assessment |
| 1015078 | Plant Support Engineering: Aging Effects for Structures and Structural Components (Structural Tools) | |||
| Spent Fuel Dry Storage Concrete Structures | AMP323 | This AMP applies to interim spent fuel dry storage concrete structures above ground. The aim of this AMP is to manage aging effects of cracking, loss of material, ingress of harmful substances, reduction in concrete pH due to leaching of calcium hydroxide, concrete carbonation, corrosion of rebar, fatigue due to cyclical loading, vibration and thermal cycling, irradiation of concrete, loss of pre-stressing force, radiation dose rate, thermal and pressure transients, boron depletion, creep and erosion. The monitoring of chemical composition of groundwater and movement and settlement are covered in AMP318, AMP307 and AMP317. The most adequate periodic inspection is visual inspection and it is supplemented using non-destructive test as well as laboratory test and analyses on samples. In addition, radiation surveys may also be performed to monitor radiation shielding effectiveness, as applicable. | ||
| Inaccessible Areas | AMP324 | This is a plant specific AMP developed for the nuclear power structures and structural components that are inaccessible for periodic inspection. The significant ageing effects are loss of material due to general corrosion and pitting, cracking due to freeze-thaw, cracking due to expansive reactions in concrete, increase in porosity and permeability due to leaching of calcium hydroxide and carbonation in inaccessible areas of structural elements of concrete and steel containments. The monitoring of groundwater chemistry should be carried out periodically to assess its impact on the structures. The most adequate inspection techniques to carry out are improved routine and in-depth examination techniques, such as non-contact NDT, embedded wireless sensors and NDT techniques with higher penetration. In addition, optical aids, such as fiberscopes and borescopes even video cameras, allow inspection of inaccessible regions. |
IGALL AMPs that are also included in the GALL[edit]
The IGALL AMPs that are also included in the GALL report, along with corresponding EPRI Guidance documents, are listed in the following table:
| AMP | IGALL | REF. EPRI | TITLE EPRI | Note |
|---|---|---|---|---|
| Low Cycle Fatigue Monitoring | AMP101 | 3002000684 | Materials Reliability Program: Thermal Fatigue Licensing Basis Monitoring Guideline MRP-149, Revision 1 | |
| 3002016012 | Materials Reliability Program: Thermal Fatigue Monitoring Guidelines MRP-32, Revision 2 | |||
| In-service Inspection/Periodic Inspection | AMP102 | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | |
| 3002010268 | Materials Reliability Program: PWR Internals Material Aging Degradation Mechanism Screening and Threshold Values (MRP-175, Revision 1) | |||
| 3002018319 | BWRVIP-167, Revision 4: BWR Vessel and Internals Project, Boiling Water Reactor Issue Management Tables | |||
| Water Chemistry | AMP103 | 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | |||
| 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | |||
| 3002017199 | BWRVIP-62 Revision 2: BWR Vessel and Internals Project: Volume 2: Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | |||
| BWR Vessel ID Attachment Welds | AMP105 | 1009948 | BWRVIP-48-A: BWR Vessel and Internals Project, Vessel ID Attachment Weld Inspection and Flaw Evaluation Guidelines | |
| 3002018321 | BWRVIP-48, Revision 2: BWR Vessel and Internals Project: Vessel ID Attachment Weld Inspection and Flaw Evaluation Guidelines | |||
| 3002002623 | style="text-align:left;" | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 3002013026 | BWRVIP-233, Rev. 2: Updated Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | |||
| 1016566 | BWRVIP-99-A: BWR Vessel and Internals Project, Crack Growth Rates in Irradiated Stainless Steels in BWR Internal Components | |||
| 3002023756 | BWRVIP-100, Revision 2: BWR Vessel and Internals Project, Updated Assessment of the Fracture Toughness of Irradiated Stainless Steel for BWR Internal Components | Revision 1 (3002008388(Archived)) is referenced in the IGALL AMP. | ||
| 3002003103 | Models of Irradiation-Assisted Stress Corrosion Cracking of Austenitic Stainless Steels in Light Water Reactor Environments: Volume 1: Disposition Curves Development; Volume 2: Disposition Curves Application | |||
| BWR Stress Corrosion Cracking in Coolant Pressure Boundary Components | AMP107 | 1012621 | BWRVIP-75-A: BWR Vessel and Internals Project, Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules | |
| 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | |||
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| 3002017199 | BWRVIP-62 Revision 2: BWR Vessel and Internals Project: Volume 2: Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | |||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 3002016000 | Materials Handbook for Nuclear Plant Pressure Boundary Applications (2019) | 2018 Revision (3002012420(Archived)) referenced in the IGALL AMP. | ||
| 3002005474 | Irradiation-Assisted Stress Corrosion Cracking (IASCC) Initiation Model for Stainless Steels | Validation of Stress Corrosion Cracking Initiation Model for Stainless Steel and Nickel Alloys (1025121(Archived)) is referenced in the IGALL AMP. | ||
| 3002018002 | Materials Reliability Program: Stress Corrosion Crack (SCC) Initiation Testing of Ni-Base Alloys for PWR Applications Part 2 (MRP-448) | |||
| BWR Penetrations | AMP108 | 1007279 | BWRVIP-27-A: BWR Vessel and Internals Project, BWR Standby Liquid Control System / Core Plate Delta-P Inspection and Flaw Evaluation Guidelines | |
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 3002013026 | BWRVIP-233, Rev. 2: Updated Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | |||
| 1016566 | BWRVIP-99-A: BWR Vessel and Internals Project, Crack Growth Rates in Irradiated Stainless Steels in BWR Internal Components | |||
| 3002023756 | BWRVIP-100, Revision 2: BWR Vessel and Internals Project, Updated Assessment of the Fracture Toughness of Irradiated Stainless Steel for BWR Internal Components | |||
| 3002005474 | Irradiation-Assisted Stress Corrosion Cracking (IASCC) Initiation Model for Stainless Steels | Validation of Stress Corrosion Cracking Initiation Model for Stainless Steel and Nickel Alloys (1025121(Archived)) is referenced in the IGALL AMP. | ||
| 3002018002 | Materials Reliability Program: Stress Corrosion Crack (SCC) Initiation Testing of Ni-Base Alloys for PWR Applications Part 2 (MRP-448) | |||
| 1009947 | BWRVIP-47-A: BWR Vessel and Internals Project, BWR Lower Plenum Inspection and Flaw Evaluation Guidelines | |||
| 1006602 | BWRVIP-49-A: BWR Vessel and Internals Project, Instrument Penetration Inspection and Flaw Evaluation Guidelines | |||
| 1008871 | BWRVIP-60-A: BWR Vessel and Internals Project, Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | |||
| TR-106712 | BWR Vessel and Internals Project: Role/Expansion Repair of Control Rod Drive and In-Core Instrument Penetrations in BWR Vessels (B WRVIP-17) | |||
| 1012120 | BWRVIP-53-A: BWR Vessel and lnternals Project, Standby Liquid Control Line Repair Design Criteria | |||
| 3002020995 | BWRVIP-57, Revision 1: BWR Vessel and Internals Project—Instrument Penetration Repair Design Criteria | |||
| 1016586 | BWRVIP-146NP, Revision 1: BWR Vessel and Internals Project, Technical Basis for ASME Code Case N-730, "Roll-Expansion of Class 1 Control Rod Drive Bottom Head Penetrations in BWRs" | |||
| BWR Vessel Internals | AMP109 | 1012837 | BWRVIP-02-A: BWR Vessel and Internals Project, BWR Core Shrould Repair Design Criteria, Rev. 2 | |
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |||
| 3002023756 | BWRVIP-100, Revision 2: BWR Vessel and Internals Project, Updated Assessment of the Fracture Toughness of Irradiated Stainless Steel for BWR Internal Components | |||
| 1007279 | BWRVIP-27-A: BWR Vessel and Internals Project, BWR Standby Liquid Control System / Core Plate Delta-P Inspection and Flaw EvaluationGuidelines | |||
| 1009947 | BWRVIP-47-A: BWR Vessel and Internals Project, BWR Lower Plenum Inspection and Flaw Evaluation Guidelines | |||
| 1008871 | BWRVIP-60-A: BWR Vessel and Internals Project, Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | |||
| 3002020995 | BWRVIP-57, Revision 1: BWR Vessel and Internals Project—Instrument Penetration Repair Design Criteria | |||
| 3002008095 | TR-105696-R19 (BWRVIP-03) Revision 19: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |||
| 1012113 | BWRVIP-16-A: BWR Vessel and Internals Project, Internal Core Spraying Piping and Sparger Replacement Design Criteria | |||
| 3002008089 | BWRVIP-18, Revision 2-A: BWR Vessel and Internals Project, BWR Core Spray Internals Inspection and Flaw Evaluation Guidelines | |||
| 1012114 | BWRVIP-19-A: BWR Vessel and Internals Project, Internal Core Spray Piping and Sparger Repair Design Criteria | |||
| 3002018310 | BWRVIP-25, Rev. 1-A, BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines | Revision 1 (3002005594(Archived)) is also referenced in the IGALL AMP. | ||
| 1009946 | BWRVIP-26-A: BWR Vessel and Internals Project, BWR Top Guide Inspection and Flaw Evaluation Guidelines | |||
| TR-108823 | BWR Vessel and Internals Project: BWR Shroud Support Inspection and Flaw Evaluation Guidelines (BWRVIP-38) | |||
| 3002003093 | BWRVIP-41, Revision 4: BWR Vessel and Internals Project, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines | |||
| 3002010548 | BWRVIP-42, Revision 1-A: BWR Vessel and Internals Project, Low Pressure Coolant Injection (LPCI) Coupling Inspection and Flaw Evaluation Guidelines | |||
| 1014352 | BWRVIP-44-A: BWR Vessel and Internals Project: Underwater Weld Repair of Nickel Alloy Reactor Vessel Internals | |||
| TR-108707 | BWR Vessel and Internals Project: Weldability of Irradiated LWR Structural Components (BWRVIP-45) | |||
| 1012115 | BWRVIP-50-A: BWR Vessel and Internals Project, Top Guide/Core Plate Repair Design Criteria | |||
| 1012116 | BWRVIP-51-A: BWR Vessel and Internals Project, Jet Pump Repair Design Criteria | |||
| 1012119 | BWRVIP-52-A: BWR Vessel and Internals Project, Shroud Support and Vessel Bracket Repair Design Criteria | |||
| 1012118 | BWRVIP-56-A: BWR Vessel and Internals Project, LPCI Coupling Repair Design Criteria | |||
| 1012618 | BWRVIP-58-A: BWR Vessel and Internals Project, CRD Internal Access Weld Repair | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 3002013026 | BWRVIP-233, Rev. 2: Updated Evaluation of Stress Corrosion Crack Growth in Low Alloy Steel Vessel Materials in the BWR Environment | |||
| 3002014434 | BWRVIP-62-A (2018 Update): BWR Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection | |||
| 3002000650 | BWRVIP-278: BWR Vessel and Internals Project, Technical Bases for Revision of the BWRVIP-76 Core Shroud Inspection Program | BWRVIP-76, Revision 2: BWR Vessel and Internals Project, BWR Core Shroud Inspection and Flaw Evaluation Guidelines (3002003095(Archived)) is referenced in IGALL AMP | ||
| 1015457 | BWRVIP-80-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Shroud Vertical Welds | |||
| 3002010552 | BWRVIP-84, Revision 3: BWRVIP Vessel and Internals Project, Guidelines for Selection and Use of Materials for Repairs to BWR Internal Components | |||
| 3002005568 | BWRVIP-97, Revision 1: BWR Vessel and Internals Project, Guidelines for Performing Weld Repairs to Irradiated BWR Internals | |||
| 1016566 | BWRVIP-99-A: BWR Vessel and Internals Project, Crack Growth Rates in Irradiated Stainless Steels in BWR Internal Components | |||
| 3002023754 | BWRVIP-138, Revision 2: BWR Vessel and Internals Project—Updated Jet Pump Beam Inspection and Flaw Evaluation Guidelines | Revision 1-A (1025139(Archived)) is referenced in IGALL AMP | ||
| 3002010541 | BWRVIP-139, Revision 1-A: BWR Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines | |||
| 3002018319 | BWRVIP-167, Revision 4: BWR Vessel and Internals Project, Boiling Water Reactor Issue Management Tables | |||
| 3002018312 | BWRVIP-180, Revision 1: BWR Vessel and Internals Project-Access Hole Cover Inspection and Flaw Evaluation Guidelines | Initial version (1013402(Archived)) is referenced in IGALL AMP | ||
| 3002005567 | BWRVIP-181, Revision 2: BWR Vessel and Internals Project, Steam Dryer Repair Design Criteria | |||
| 1020802 | BWRVIP-182-A: BWR Vessel and Internals Project, Guidance for Demonstration of Steam Dryer Integrity for Power Uprate | |||
| 3002010551 | BWRVIP-183-A: BWR Vessel and Internals Project, Top Guide Grid Beam Inspection and Flaw Evaluation Guidelines | |||
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| 3002010550 | BWRVIP-234-A: BWR Vessel and Internals Project, Thermal Aging and Neutron Embrittlement of Cast Austenitic Stainless Steels for BWR Internals | |||
| 3002012535 | BWRVIP-315: BWR Vessel and Internals Project, Reactor Internals Aging Management Evaluation for Extended Operations | |||
| PWR Boric Acid Corrosion | AMP110 | 1025145 | Materials Reliability Program: Boric Acid Corrosion Guidebook, Revision 2: Managing Boric Acid Corrosion Issues at PWR Power Stations (MRP-058, Rev 2) | |
| PWR Cracking of Nickel Alloy Reactor Coolant Pressure Boundary Components | AMP111 | 1016591 | Materials Reliability Program: Safety Evaluation for Boric Acid Wastage of PWR Reactor Vessel Bottom Heads Due to Bottom-Mounted Nozzle Leakage (MRP-167) | |
| 1025145 | Materials Reliability Program: Boric Acid Corrosion Guidebook, Revision 2: Managing Boric Acid Corrosion Issues at PWR Power Stations (MRP-058, Rev 2) | |||
| 1015009 | MRP-139 Revision 1: Primary System Piping Butt Welds Inspection and Evaluation Guideline | |||
| 3002014244 | Materials Reliability Program: Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Thick-Wall Alloy 600 Materials and Alloy 82, 182, and 132 Welds (MRP-420, Revision 1) | |||
| 3002010756 | Materials Reliability Program: Recommended Factors of Improvement for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) Growth Rates of Thick-Wall Alloy 690 Materials and Alloy 52, 152, and Variants Welds (MRP 386) | |||
| Thermal Ageing Embrittlement of Cast Austenitic Stainless Steel | AMP112 | 3002005571 | TR-105696-R18 (BWRVIP-03) Revision 18: BWR Vessel and Internals Project, Reactor Pressure Vessel and Internals Examination Guidelines | |
| 3002010675 | BWRVIP-03, Revision 20: BWR Vessel and Internals Project-Reactor Pressure Vessel and Internals Examination Guidelines | |||
| PWR Vessel Internals | AMP113 | 3002026460 | Materials Reliability Program: Inspection Standard for Pressurized Water Reactor Internals - 2023 Update (MRP-228, Rev. 5) | Revision 4 (3002018245(Archived)) is reference in IGALL AMP |
| 3002020105 | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227, Revision 2) | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines MRP-227-A (1022863(Archived)) is also referenced in the IGALL In addition EPRI submits a bienial letter to US NRC detailing MRP-227-A results for the previous 24 months. | ||
| 3002017168 | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227, Revision 1-A) | |||
| 3002003083 | Materials Reliability Program: Improvement of the Cluster Dynamics Model for the Prediction of Void Swelling in Austenitic Stainless Steel (MRP-391) | |||
| 3002010268 | Materials Reliability Program: PWR Internals Material Aging Degradation Mechanism Screening and Threshold Values (MRP-175, Revision 1) | Initial Revision (1012081(Archived)) is also referenced in the IGALL AMP | ||
| Flow Accelerated Corrosion and Erosion | AMP114 | 3002008071 | Flow-Accelerated Corrosion in Power Plants: Revision 2 | |
| 3002000563 | Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R4) | |||
| 3002023786 | Recommendations for an Effective Program Against Erosive Attack: Revision 1 | Initial Revision (3002005530(Archived)) is referenced in the IGALL AMP | ||
| 3002010594 | CHECWORKS™ Steam/Feedwater Application Guidelines for Plant Modeling and Evaluation of Component Inspection Data: Revision 1 | |||
| Bolting Integrity | AMP115 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Degradation and Failure of Bolting in Nuclear Power Plants (NP-5769(Archived)) is referenced in the IGALL AMP |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Steam Generators | AMP116 | 3002020909 | Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines, Revision 5 | Revision 4 (3002007571(Archived)) is referenced in the IGALL AMP |
| 3002007572 | Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 8 | |||
| 3002007856 | Steam Generator Management Program: Steam Generator In Situ Pressure Test Guidelines, Revision 5 | Revision 4 (1025132(Archived)) is referenced in the IGALL AMP | ||
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | |||
| 3002010645 | Pressurized Water Reactor Secondary Water Chemistry Guidelines: Revision 8 | |||
| LR-ISG-2016-01(No longer an EPRI maintained document) | Changes to Aging Management Guidance for Various Steam Generator Components | Changes to Aging Management Guidance for Steam Generator Chanel Head Components (SGMP-IL-16-02(Archived)) is reference in the IGALL AMP but has since been transferred to NRC as LR-ISG-2016-01 | ||
| 3002002850 | Steam Generator Management Program: Investigation of Crack Initiation and Propagation in the Steam Generator Channel Head Assembly | |||
| 3002018267 | Steam Generator Management Program: PWR Primary-to-Secondary Leak Guidelines-Revision 5 | Revision 4 (1022832(Archived)) is referenced in the IGALL AMP | ||
| Closed Treated Water Systems | AMP117 | 3002000590 | Closed Cooling Water Chemistry Guideline: Revision 2 | |
| Reactor Vessel Surveillance | AMP118 | 3002018322 | Materials Handbook for Nuclear Plant Pressure Boundary Applications (2020) | Application of Master Curve Fracture Toughness Methodology for Ferritic Steels (PWRMRP-01): PWR Materials Reliability Project (PWRMRP), Final Report (TR-108390-R1(Archived)) is also referenced in the IGALL AMP Materials Reliability Program: Developing on Embrittlement Trend Curve Using the Charpy “Master Curve” Transition Reference Temperature (MRP-289) (1020703(Archived)) is also referenced in the IGALL AMP |
| 3002016008 | Technical Basis for ASME Code Case N-830-1, Revision 1 (MRP-418, Revision 1): Direct Use of Master Curve Fracture Toughness for Pressure-Retaining Materials of Class 1 Vessels, Section XI | |||
| 3002003040 | Materials Reliability Program: Development of a T0-Based Embrittlement Trend Curve and Comparison With the Charpy Master Curve Embrittlement Trend Curve (MRP-389) | |||
| 3002023871 | Materials Reliability Program: Technical Basis and Implied Margins of ASME Code, Section XI, Appendix G (MRP-450, Revision 1): Fracture Toughness Criteria for Protection Against Failure | |||
| 3002013223 | Materials Reliability Program: Consolidated Fracture Toughness Models for Ferritic RPV Steels (MRP-432) | |||
| 1025144 | BWRVIP-86, Revision 1-A: BWR Vessel and Internals Project, Updated BWR Integrated Surveillance Program (ISP) Implementation Plan | |||
| One-time Inspection | AMP119 | 3002010675 | BWRVIP-03, Revision 20: BWR Vessel and Internals Project-Reactor Pressure Vessel and Internals Examination Guidelines | |
| 3002026460 | Reliability Program: Inspection Standard for Pressurized Water Reactor Internals - 2023 Update (MRP-228, Rev. 5) | Revision 3 (3002010399(Archived)) is referenced in the IGALL AMP | ||
| 1022931 | Nondestructive Evaluation: Update on License Renewal One Time Inspection and Best NDE Practices | |||
| Selective Leaching | AMP120 | TR-107514 | Age-Related Degradation Inspection Method and Demonstration: In Behalf of Calvert Cliffs Nuclear Power Plant License Renewal Application | |
| 3002013168 | Nondestructive Evaluation: Guidance for Conducting Ultrasonic Examinations for the Detection of Selective Leaching | |||
| 3002016057 | Selective Leaching: State-of-the-Art Technical Update | |||
| 1018939 | Nondestructive Evaluation: NDE for Selective Leaching of Gray Cast Iron Components | |||
| 1019111 | Nondestructive Evaluation: Update to NDE for Selective Leaching of Gray Cast Iron Components | |||
| 1025218 | Nondestructive Evaluation: Correlation of Selectively Leached Thickness to Hardness for Gray Cast Iron and Brass | |||
| 1010639 | Non-Class 1 Mechanical Implementation Guideline and Mechanical Tools | |||
| 3002008013 | Assessment of Available Nondestructive Evaluation Techniques for Selective Leaching: Technology Review | |||
| 3002020830 | Ultrasonic NDE Techniques for Detection of Selective Leaching in Complex Shaped Gray Cast Iron Components | |||
| 3002020832 | Electromagnetic NDE Techniques for Detection of Selective Leaching in Gray Cast Iron Piping | |||
| 3002020713 | Leveraging Risk Insights for Aging Management Program Implementation: 2022 | Initial revision (3002018403(Archived)) is referenced in IGALL AMP | ||
| 3002020822 | Accelerated Testing and Evaluation of Factors Affecting Selective Leaching Susceptibility | |||
| One-time Inspection of Class 1 Small Bore Piping | AMP121 | 3002007853 | Materials Reliability Program: Management of Thermal Fatigue in Normally Stagnant Non-Isolable Reactor Coolant System Branch Lines (MRP-146, Revision 2) | |
| 1018330 | Materials Reliability Program: Management of Thermal Fatigue in Normally Stagnant Non-Isolable Reactor Coolant System Branch Lines -Supplemental Guidance (MRP-146S) | |||
| 3002013099 | BWRVIP-196, Revision 1: BWR Vessel and Internals Project: Assessment of Mixing Tee Thermal Fatigue Susceptibility in BWR Plant | |||
| 3002013098 | BWRVIP-155, Revision 1: BWR Vessel and Internals Project: Evaluation of Thermal Fatigue Susceptibility in BWR Stagnant Branch Lines | |||
| 1003666 | Materials Reliability Program: Lessons Learned from PWR Thermal Fatigue Management Training (MRP-83) | |||
| 3002000505 | Pressurized Water Reactor Primary Water Chemistry Guidelines: Revision 7, Volumes 1 and 2 | |||
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| Open Cycle Cooling Water System | AMP124 | 1010059 | Service Water Piping Guideline | |
| 1008282 | Life Cycle Management Sourcebook for Nuclear Plant Service Water Systems | |||
| NP-4582 | A Study of Microbiologically Influenced Corrosion in Nuclear Power Plants and a Practical Guide for Countermeasures | |||
| Buried and Underground Piping and Tanks | AMP125 | 3002004395 | Nondestructive Evaluation: Buried Pipe NDE Reference Guide—Revision 3 | Nondestructive Evaluation: Remote Field Technology Assessment for Piping Inspection, Including Buried and Limited Access Components (1021153(Archived)) is also reference in the IGALL AMP |
| 3002010027 | Nondestructive Evaluation: Assessment and Development of Buried Pipe NDE Technology, Revision 1 | |||
| 1025231 | Nondestructive Evaluation: Buried Pipe In-Line NDE Depth Sizing Procedure | |||
| 3002008032 | Development and Evaluation of Guided Wave Structural Health Monitoring for Buried Pipe | |||
| 3002000468 | Obtaining Credit for Guided Wave as a Buried Pipe Direct Examination | |||
| 1019115 | Buried Pipe Guided Wave Examination Reference Document | |||
| 3002018352 | Recommendations for an Effective Program to Control the Degradation of Buried and Underground Piping and Tanks (1016456, Revision 2) | |||
| 3002002949 | Recommendations for Managing an Effective Cathodic Protection System | |||
| Boraflex Monitoring | AMP126 | NP-6159 | An Assessment of Boraflex Performance in Spent-Nuclear-Fuel Storage Racks | |
| TR-101986 | Boraflex Test Results and Evaluation | |||
| TR-103300 | Guidelines for Boraflex Use in Spent-Fuel Storage Racks | |||
| 1003413 | Guidance and Recommended Procedures for Maintaining and Using RACKLIFE Version 1.10 Models | |||
| 1019110 | Handbook of Neutron Absorber Materials for Spent Nuclear Fuel Transportation and Storage Applications | |||
| Compressed Air Monitoring | AMP128 | 3002022576 | Compressed Air Systems and Equipment Guide: Update and Consolidation of TR-108147 and 1006677 | This document is the current revision of: Instrument Air System: A Guide for Power Plant Maintenance Personnel (NP-7079(Archived)) and Compressor and Instrument Air System Maintenance Guide: Revision to NP-7079 (TR-108147(Archived)) which are referenced in the IGALL AMP |
| BWR Reactor Water Cleanup System | AMP129 | 1012621 | BWRVIP-75-A: BWR Vessel and Internals Project, Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules | |
| 3002002623 | BWRVIP-190 Revision 1: BWR Vessel and Internals Project, Volume 1: BWR Water Chemistry Guidelines - Mandatory, Needed, and Good Practice Guidance and Volume 2: BWR Water Chemistry Guidelines - Technical Basis | |||
| 1016569 | BWRVIP-14-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Stainless Steel RPV Internals | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| Fuel Oil Chemistry | AMP133 | 1015061 | Nuclear Maintenance Applications Center: Guide for the Storage and Handling of Fuel Oil for Standby Diesel Generator Systems, Revision 3 | |
| 3002010609 | Storage and Use of Low-Concentration (5%) Biodiesel Blends in Nuclear Plant Emergency Diesel Generators | |||
| TR-104843 | Winterizing Diesel Fuel | |||
| External Surfaces Monitoring of Mechanical Components | AMP134 | 1007933 | style="text-align:left;" | Aging Assessment Field Guide | |
| 1009743 | Aging Identification and Assessment Checklist: Mechanical Components | |||
| 3002011822 | Long-Term Operations: Subsequent License Renewal Non-Class 1 Mechanical Implementation Guideline and Mechanical Tools | |||
| Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components | AMP135 | 1009743 | Aging Identification and Assessment Checklist: Mechanical Components | |
| CANDU/PHWR Feeder Piping | AMP140 | 1009561 | Materials Reliability Program: Generic Guidance for Alloy 600 Management (MRP-126) | |
| Safety Related Pumps | AMP144 | TR-107252 | Centrifugal and Positive Displacement Charging Pump Maintenance Guide | |
| CANDU/PHWR Moderator and Moderator Purification Heat Exchangers | AMP145 | 1018089 | Nuclear Maintenance Applications Center: Heat Exchanger Maintenance Guide | Heat exchangers: Over of Maintenance and Operation (TR-106741(Archived)) is referenced in the IGALL AMP |
| PMBD | Preventive Maintenance Basis, Volume 32: Heat Exchangers – Tube Type | Preventive Maintenance Basis, Volume 32: Heat Exchangers – Tube Type (TR-106857(Archived)) is referenced in the IGALL AMP | ||
| 1003320 | Supplemental Guidance for Testing and Monitoring Service Water Heat Exchangers | Balance-of-Plant Heat Exchanger Condition Assessment and Inspection Guide (TR-108009(Archived)) is referenced in the IGALL AMP | ||
| 3002005340 | Service Water Heat Exchanger Testing Guidelines | |||
| NP-7552 | Heat Exchangers Performance Monitor Guidelines | |||
| CANDU/PHWR Inspection Programmes | AMP146 | 3002000563 | Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R4) | |
| 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | |||
| Containment Bellows | AMP147 | 1008035 | Expansion Joint Maintenance Guide | |
| PWR Residual Heat Removal Heat Exchangers | AMP155 | 1018089 | Nuclear Maintenance Applications Center: Heat Exchanger Maintenance Guide | Heat exchangers: Over of Maintenance and Operation (TR-106741(Archived)) is referenced in the IGALL AMP |
| PMBD | Preventive Maintenance Basis, Volume 32: Heat Exchangers | Preventive Maintenance Basis, Volume 32: Heat Exchangers – Tube Type (TR-106857(Archived)) is referenced in the IGALL AMP | ||
| NP-7552 | Heat Exchanger Performance Monitoring Guidelines | |||
| Internal Coatings and Linings | AMP157 | 1019157 | Plant Support Engineering: Guideline on Nuclear Safety-Related Coatings, Revision 2 (Formerly TR-109937 and 1003102) | |
| PWR Emergency Core Cooling System Hydro-Accumulators | AMP159 | 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | |
| High Cycle Fatigue Monitoring | AMP161 | 3002016011 | Materials Reliability Program: Temperature Monitoring Data Evaluation for Reactor Coolant System Branch Lines Subject to Thermal Fatigue (MRP-365, Revision 1) | |
| 3002007853 | Materials Reliability Program: Management of Thermal Fatigue in Normally Stagnant Non-Isolable Reactor Coolant System Branch Lines (MRP-146, Revision 2) | |||
| 3002013099 | BWRVIP-196, Revision 1: BWR Vessel and Internals Project: Assessment of Mixing Tee Thermal Fatigue Susceptibility in BWR Plant | |||
| 1022563 | Materials Reliability Program: Thermal Fatigue Monitoring Guidelines (MRP-32, Revision 1) | |||
| 3002017285 | NDE Technology for Detection of Thermal Fatigue Damage in Piping, MRP-23 Revision 3 | |||
| 3002018246 | Materials Reliability Program: Fatigue Management Handbook (MRP-235, Revision 3) | |||
| 3002023891 | Materials Reliability Program: Assessment of Residual Heat Removal Mixing Tee Thermal Fatigue in PWR Plants (MRP-192, Revision 4) | Revision 3 (3002013266(Archived)) is referenced in the IGALL AMP | ||
| 3002013098 | BWRVIP-155, Revision 1: BWR Vessel and Internals Project: Evaluation of Thermal Fatigue Susceptibility in BWR Stagnant Branch Lines | |||
| 3002013263 | Materials Reliability Program: Operating Experience Regarding Thermal Fatigue of Piping Connected to PWR Reactor Coolant Systems (MRP-85, Revision 2) | |||
| PWR Reactor Pressure Vessel | AMP162 | 3002016009 | Materials Reliability Program: Effects of Thermal Ageing on Reactor Coolant System Pressure Boundary Materials (MRP-438), Low Alloy Ferritic Steels | |
| 3002017168 | Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227, Revision 1-A) | |||
| Dissimilar Metal Welds | AMP163 | 1006603 | Materials Reliability Program: GE Experience Report on Cracking in Alloy 182 (MRP-57): BWR Alloy 182 Stress Corrosion Cracking | |
| 3002013781 | EPRI Materials Degradation Matrix, Revision 4 | |||
| 1014874 | BWRVIP-59-A: BWR Vessel and Internals Project, Evaluation of Crack Growth in BWR Nickel Base Austenitic Alloys in RPV Internals | |||
| 1012621 | BWRVIP-75-A: BWR Vessel and Internals Project, Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules | |||
| 1015009 | MRP-139 Revision 1: Primary System Piping Butt Welds Inspection and Evaluation Guideline | |||
| 1003523 | Materials Reliability Program: A Review of Thermal Aging Embrittlement in Pressurized Water Reactors (MRP-80) | |||
| 1021023 | Materials Reliability Program: Primary Water Stress Corrosion Cracking (PWSCC) Flaw Evaluation Guidance (MRP-287) | |||
| 3002012244 | Nondestructive Evaluation: Guideline for Conducting Ultrasonic Examinations of Dissimilar Metal Welds, Revision 3 | |||
| 1015400 | Materials Reliability Program: Advanced FEA Evaluation of Growth of Postulated Circumferential PWSCC Flaws in Pressurizer Nozzle Dissimilar Metal Welds (MRP-216, Rev. 1) | Initial revision (1015383(Archived)) is referenced in IGALL AMP | ||
| 1009378 | Materials Reliability Program: Welding Residual and Operating Stresses in PWR Alloy 182 Butt Welds (MRP-106) | |||
| 1009549 | Materials Reliability Program: Alloy 82/182 Pipe Butt Weld Safety Assessment for U.S. PWR Plant Designs (MRP-113) | |||
| 1009559 | Materials Reliability Program: Evaluation of the Effect of Weld Repairs on Dissimilar Metal Butt Welds (MRP-114) | |||
| 1009805 | Materials Reliability Program: Alloy 82/182 Pipe Butt Weld Safety Assessment for US PWR Plant Designs: Babcock & Wilcox Design Plants (MRP-112) | |||
| 1006696 | Materials Reliability Program: Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82, 182, and 132 Welds (MRP-115) | |||
| 1009806 | Materials Reliability Program: Probabilistic Risk Assessment of Alloy 82/182 Piping Butt Welds (MRP-116) | |||
| Outdoor Piping, Tanks and Structures | AMP164 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Good Bolting Practices: A Reference Manual for Nuclear Power Plant Maintenance Personnel, Volume 1: Large Bolt Manual (NP-5067(Archived)) is referenced in the IGALL AMP |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Electrical Insulation for Electrical Cables and Connections Not Subject to Equipment Qualification Requirements | AMP201 | TR-109619 | Guideline for the Management of Adverse Localized Equipment | |
| TR-017218-R1 | Guideline for Sampling in the Commercial-Grade Item Acceptance Process | |||
| 1021070 | Medium Voltage Cable Aging Management Guide, Revision 1 | |||
| 3002000557 | Plant Engineering, Aging Management Program Guidance for Medium-Voltage Cable Systems for Nuclear Power Plants, Revision 1 | |||
| 1024044 | Aging Power Cable Maintenance Guideline | |||
| 1022969 | Plant Engineering: Electrical Cable Test Applicability Matrix for Nuclear Power Plants | |||
| TR-107514 | Age-Related Degradation Inspection Method and Demonstration: In Behalf of Calvert Cliffs Nuclear Power Plant License Renewal Application | |||
| 3002010641 | Low-Voltage and Instrumentation and Control Cable Aging Management Guide, Revision 1 | |||
| Electrical Insulation for Electrical Cables and Connections Not Subject to Equipment Qualification Requirements Used in Instrumentation Circuits | AMP202 | TR-110379 | High Range Radiation Monitor Cable Study: Phase I | |
| TR-109619 | Guideline for the Management of Adverse Localized Equipment | |||
| 3002010641 | Low-Voltage and Instrumentation and Control Cable Aging Management Guide, Revision 1 | |||
| TR-112582 | High Range Radiation Monitor Cable Study: Phase II | |||
| Electrical Insulation for Inaccessible Instrumentation and Control and Low and Medium Voltage Power Cables Not Subject to Equipment Qualification Requirements | AMP203 | 3002007991 | Plant Engineering: Low-Voltage Cable Susceptibility to Wet Aging | |
| TR-109619 | Guideline for the Management of Adverse Localized Equipment | |||
| 1021070 | Medium Voltage Cable Aging Management Guide, Revision 1 | |||
| 3002000557 | Plant Engineering, Aging Management Program Guidance for Medium-Voltage Cable Systems for Nuclear Power Plants, Revision 1 | |||
| 1022969 | Plant Engineering: Electrical Cable Test Applicability Matrix for Nuclear Power Plants | |||
| 3002010641 | Low-Voltage and Instrumentation and Control Cable Aging Management Guide, Revision 1 | |||
| 1025262 | Plant Engineering: Evaluation and Insights from Nuclear Power Plant Tan Delta Testing and Data Analysis | |||
| 3002000576 | Long-Term Operations Program: Assessment of Research and Development Supporting Aging Management Programs for Long-Term Operation | |||
| Metal Enclosed Bus Not Subject to Equipment Qualification Requirements | AMP204 | 1013457 | Nuclear Maintenance Applications Center: Switchgear and Bus Maintenance Guide | |
| Electrical Cable Connections Not Subject to Equipment Qualification Requirements | AMP206 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 | Initial version (1015336(Archived)) is referenced in the IGALL AMP |
| High Voltage Insulators and Transmission Conductors | AMP208 | 3002026920 | Overhead Transmission Inspection, Assessment, and Asset Management Reference Guide—2023 | Parameters that Influence the Aging and Degradation of Overhead Conductors (1001997(Archived)) is referenced in the IGALL AMP |
| 1000174 | Oconee Electrical Component Integrated Plant Assessment and Time Limited Aging Analyses for License Renewal: Revision 1 | |||
| 3002010401 | Long-Term Operations: Subsequent License Renewal Electrical Handbook | |||
| Condition Monitoring of Electrical and I&C Cables Subject to Equipment Qualification Requirements | AMP210 | 1021067 | Plant Support Engineering: Nuclear Power Plant Equipment Qualification Reference Manual, Revision 1 | |
| 1021070 | Medium Voltage Cable Aging Management Guide, Revision 1 | |||
| 3002000557 | Plant Engineering, Aging Management Program Guidance for Medium-Voltage Cable Systems for Nuclear Power Plants, Revision 1 | |||
| 1024044 | Aging Power Cable Maintenance Guideline | |||
| 1022969 | Plant Engineering: Electrical Cable Test Applicability Matrix for Nuclear Power Plants | |||
| 3002010641 | Low-Voltage and Instrumentation and Control Cable Aging Management Guide, Revision 1 | |||
| 1008211 | Initial Acceptance Criteria Concepts and Data for Assessing Longevity of Low-Voltage Cable Insulations and Jackets | |||
| 1015209 | Plant Support Engineering: Line Impedance Resonance Analysis for the Detection of Cable Damage and Degradation | |||
| 1001391 | Training Aids for Visual / Tactile Inspection of Electrical Cables for Detection of Aging | |||
| TR-106687 | Cable Aging Management Program for D.C. Cook Nuclear Plant Units 1 and 2 | |||
| 3002012582 | Infrared Thermography Guide | Previous revision (1006524(Archived)) is referenced in the IGALL AMP | ||
| 1022968 | Plant Engineering: Cable Aging Management Program Implementation Guidance | |||
| 3002005322 | Plant Engineering: Cable Polymer Handbook - Medium Voltage Insulations | |||
| 3002010591 | Effects of 0.1 Hertz Withstand Testing on Medium-Voltage Cable Insulation | |||
| 3002018283 | A Review of Equipment Aging Theory and Technology: Revision 1 of NP-1558 | |||
| Equipment Qualification Preservation and Reassessment | AMP221 | 3002010401 | Long-Term Operations: Subsequent License Renewal Electrical Handbook | |
| 1021067 | Plant Support Engineering: Nuclear Power Plant Equipment Qualification Reference Manual, Revision 1 | |||
| Fans Used in I&C and Power Electronics Cabinets | AMP226 | PMBD | “EPRI Preventive Maintenance Basis Database (PMBD)”, Inverter template | |
| In-service Inspection for Containment Steel Elements | AMP301 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Degradation and Failure of Bolting in Nuclear Power Plants (NP-5769(Archived)), Good Bolting Practices: A Reference Manual for Nuclear Power Plant Maintenance Personnel, Volume 1: Large Bolt Manual (NP-5067(Archived)), and Bolted Joint Maintenance and Applications Guide (TR-104213(Archived)) are referenced in the IGALL AMP. |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| TR-114881 | Aging Effects for Structures and Structural Components (Structural Tools): B&W Owners Group Generic License Renewal Program, BAW-2279P, 1997 | |||
| 3002013084 | Long-Term Operations: Subsequent License Renewal Aging Effects for Structures and Structural Components (Structural Tools) | |||
| TR-104514 | How to Conduct Material Condition Inspections: September, 1994 | |||
| Safety Class 1, 2 and 3 Piping and Metal Containment Components Supports | AMP303 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Degradation and Failure of Bolting in Nuclear Power Plants (NP-5769(Archived)), Good Bolting Practices: A Reference Manual for Nuclear Power Plant Maintenance Personnel, Volume 1: Large Bolt Manual (NP-5067(Archived)), and Bolted Joint Maintenance and Applications Guide (TR-104213(Archived)) are referenced in the IGALL AMP. |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Masonry Walls | AMP305 | 3002013084 | Long-Term Operations: Subsequent License Renewal Aging Effects for Structures and Structural Components (Structural Tools) | |
| Water Control Structures | AMP307 | 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Good Bolting Practices: A Reference Manual for Nuclear Power Plant Maintenance Personnel, Volume 1: Large Bolt Manual (NP-5067(Archived)), and Bolted Joint Maintenance and Applications Guide (TR-104213(Archived)) are referenced in the IGALL AMP. |
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| Protective Coating Monitoring and Maintenance Programme | AMP308 | 1025323 | Field Guide: Coatings Assessment | |
| 1019157 | Plant Support Engineering: Guideline on Nuclear Safety-Related Coatings, Revision 2 (Formerly TR-109937 and 1003102) | |||
| Concrete Structures Monitoring | AMP318 | 1011224 | Aging Identification and Assessment Checklist: Civil and Structural Components | |
| 1007933 | Aging Assessment Field Guide | |||
| Non-concrete structures monitoring | AMP319 | 1007933 | Aging Assessment Field Guide | |
| 3002015824 | Nuclear Maintenance Applications Center: Bolted Joint Fundamentals, Revision 1 |
Degradation and Failure of Bolting in Nuclear Power Plants ((Archived)), Good Bolting Practices: A Reference Manual for Nuclear Power Plant Maintenance Personnel, Volume 1: Large Bolt Manual (NP-5067(Archived)), and Nuclear Maintenance Applications Center: Bolted Joint Fundamentals (1015336(Archived)) are referenced in the IGALL AMP | ||
| 3002023823 | Assembling Gasketed Bolted Flange Joints: Update of Report 3002008061 | |||
| 1011224 | Aging Identification and Assessment Checklist: Civil and Structural Components |
Record of Revisions[edit]
| Number | Date | Description of Changes |
|---|---|---|
| 0 | 6/11/2024 | Initial version |