1801 R0 X.M1: Difference between revisions
en>Monica Hurley (Created page with "{{DISPLAYTITLE:X.M1 (NUREG-1801 R0)}} Return to AMP Table '''X.M1 METAL FATIGUE OF REACTOR COOLANT PRESSURE BOUNDARY''' '''Program Description''' In order not to exceed the design limit on fatigue usage, the aging management program (AMP) monitors and tracks the number of critical thermal and pressure transients for the selected reactor coolant system components. The AMP addresses the effects of the coolant enviro...") |
m (1 revision imported: Initial page creation) |
(No difference)
| |
Revision as of 19:12, 4 October 2024
X.M1 METAL FATIGUE OF REACTOR COOLANT PRESSURE BOUNDARY
Program Description
In order not to exceed the design limit on fatigue usage, the aging management program (AMP) monitors and tracks the number of critical thermal and pressure transients for the selected reactor coolant system components.
The AMP addresses the effects of the coolant environment on component fatigue life by assessing the impact of the reactor coolant environment on a sample of critical components that includes, as a minimum, those components selected in NUREG/CR-6260. The sample of critical components can be evaluated by applying environmental correction factors to the existing ASME Code fatigue analyses. Formulas for calculating the environmental life correction factors are contained in NUREG/CR-6583 for carbon and low-alloy steels and in NUREG/CR-5704 for austenitic stainless steels.
As evaluated below, this is an acceptable option for managing metal fatigue for the reactor coolant pressure boundary, considering environmental effects. Thus, no further evaluation is recommended for license renewal if the applicant selects this option under 10 CFR 54.21(c)(1)(iii) to evaluate metal fatigue for the reactor coolant pressure boundary.
Evaluation and Technical Basis
- 1. Scope of Program: The program includes preventive measures to mitigate fatigue cracking of metal components of the reactor coolant pressure boundary caused by anticipated cyclic strains in the material.
- 2. Preventive Actions: Maintaining the fatigue usage factor below the design code limit and considering the effect of the reactor water environment, as described under the program description, will provide adequate margin against fatigue cracking of reactor coolant system components due to anticipated cyclic strains.
- 3. Parameters Monitored/Inspected: The program monitors all plant transients that cause cyclic strains, which are significant contributions to the fatigue usage factor. The number of plant transients that cause significant fatigue usage for each reactor coolant pressure boundary component is to be monitored. Alternatively, more detailed local monitoring of the plant transient may be used to compute the actual fatigue usage for each transient.
- 4. Detection of Aging Effects: The program provides for periodic update of the fatigue usage calculations.
- 5. Monitoring and Trending: The program monitors a sample of high fatigue usage locations. As a minimum, this sample is to include the locations identified in NUREG/CR-6260.
- 6. Acceptance Criteria: The acceptance criteria involves maintaining the fatigue usage below the design code limit considering environmental fatigue effects as described under the program description.
- 7. Corrective Actions: The program provides for corrective actions to prevent the usage factor from exceeding the design code limit during the period of extended operation.
- Acceptable corrective actions include a more rigorous analysis of the component to demonstrate that the design code limit will not be exceeded, repair, or replacement of the component. For programs that monitor a sample of high fatigue usage locations, corrective actions include a review of additional affected reactor coolant pressure boundary locations.
- 8. Conformation Process: Site quality assurance procedures, review and approval processes and administrative controls are implemented in accordance with the requirements of Appendix B to 10 CFR Part 50. As discussed in the appendix to this report, the staff finds the requirements of 10 CFR Part 50, Appendix B, acceptable in addressing the confirmation process and administrative controls.
- 9. Administrative Controls: See Item 8, above.
- 10. Operating Experience: The program reviews industry experience regarding fatigue cracking. Applicable experience with fatigue cracking is to be considered in selecting the monitored locations.
References
NUREG/CR-5704, Effects of LWR Coolant Environments on Fatigue Design Curves of Austenitic Stainless Steels, U.S. Nuclear Regulatory Commission, April 1999.
NUREG/CR-6260, Application of NUREG/CR-5999 Interim Fatigue Curves to Selected Nuclear Power Plant Components, U.S. Nuclear Regulatory Commission, March 1995.
NUREG/CR-6583, Effects of LWWR Coolant Environments on Fatigue Design Curves of Carbon and Low-Alloy Steels, U.S. Nuclear Regulatory Commission, March 1998.