XI.M33 (NUREG-2191 R0)

From EPRI Nuclear LTO Wiki
Revision as of 19:12, 4 October 2024 by Monica Hurley (talk | contribs) (1 revision imported: Initial page creation)
Jump to navigation Jump to search

Return to AMP Table


XI.M33 SELECTIVE LEACHING


Program Description

The program for selective leaching (dealloying) of materials includes components made of gray cast iron, ductile iron, and copper alloys (except for inhibited brass) that contain greater than 15 percent zinc or greater than 8 percent aluminum exposed to a raw water, closed-cycle cooling water (CCCW), treated water, waste water, or soil environment. Depending on the environment, the aging management program (AMP) includes one-time, or opportunistic or periodic visual inspections of selected components that are susceptible to selective leaching, coupled with mechanical examination techniques (e.g., chipping, scraping). Destructive examinations of components to determine the presence of and depth of dealloying through-wall thickness are also conducted. These techniques can determine whether loss of material due to selective leaching is occurring and whether selective leaching will affect the ability of the components to perform their intended function for the subsequent period of extended operation.

The selective leaching process involves the preferential removal of one of the alloying components from the material. Dezincification (loss of zinc from brass) and graphitization or graphitic corrosion (removal of iron from gray cast iron and ductile iron) are examples of such a process. Susceptible materials exposed to high operating temperatures, stagnant-flow conditions, and a corrosive environment (e.g., acidic solutions for brasses with high zinc content and dissolved oxygen) are conducive to selective leaching. A dealloyed component often retains its shape and may appear to be unaffected; however, the functional cross-section of the material has been reduced. The aging effect attributed to selective leaching is loss of material because the affected volume has a permanent change in density and does not retain mechanical properties that can be credited for structural integrity.


Evaluation and Technical Basis

1. Scope of Program: Components include piping, valve bodies and bonnets, pump casings, and heat exchanger components that are susceptible to selective leaching. The materials of construction for these components may include gray cast iron, ductile iron, and copper alloys (except for inhibited brass) containing greater than 15 percent zinc or greater than 8 percent aluminum. These components may be exposed to raw water, CCCW, treated water, waste water, or soil.
Depending on plant-specific operating experience (OE) and implementation of preventive actions, certain components may be excluded from the scope of this program in each 10-year inspection interval as follows:
2. Preventive Actions: Although the program does not provide guidance on preventive actions, water chemistry control of certain parameters (e.g., pH, concentration of corrosive contaminants, dissolved oxygen), cathodic protection, and coatings can be effective in minimizing selective leaching.
3. Parameters Monitored or Inspected: This program monitors visual appearance (e.g., color, porosity, abnormal surface conditions), surface conditions through mechanical examination techniques (e.g., chipping, scraping), and the presence of and depth of dealloying through-wall thickness through destructive examinations.
4. Detection of Aging Effects: Inspections and examinations consist of the following:
  • Visual inspections of all accessible surfaces. In certain copper-based alloys selective leaching can be detected by visual inspection through a change in color from a normal yellow color to a reddish copper color or green copper oxide. Graphitized cast iron cannot be reliably identified through visual examination, as the appearance of the graphite surface layer created by selective leaching does not always differ appreciably from the typical cast iron surface.
  • Mechanical examination techniques, such as chipping and scraping, augment visual inspections for gray cast iron and ductile iron components.
  • Destructive examinations are used to determine the presence of and depth of dealloying through-wall thickness of components.
One-time and periodic inspections are conducted of a representative sample of each population. A population is defined as the same material and environment combination. Opportunistic inspections are conducted whenever components are opened, or buried or submerged surfaces are exposed.
One-time inspections are only conducted for components exposed to CCCW or treated water when no plant-specific OE of selective leaching exists in these environments. In the 10-year period prior to a subsequent period of extended operation, a sample of 3 percent of the population or a maximum of 10 components per population at each unit are visually and mechanically (for gray cast iron and ductile iron components) inspected. Inspections, where possible, focus on the bounding or lead components most susceptible to aging based on time-in-service and severity of operating conditions for each population.
Opportunistic and periodic inspections are conducted for components exposed to raw water, waste water, or soil, and for components in CCCW or treated water where plant-specific OE includes selective leaching in these environments. Opportunistic inspections are conducted whenever components are opened, or buried or submerged surfaces are exposed. Periodic inspections are conducted in the 10-year period prior to a subsequent period of extended operation and in each 10-year period during a subsequent period of extended operation. If the inspection conducted for ductile iron in the 10-year period prior to a subsequent period of extended operation (i.e., the initial inspection) meets acceptance criteria, periodic inspections do not need to be conducted during the subsequent period of extended operation for ductile iron. In these periodic inspections, a sample of 3 percent of the population or a maximum of 10 components per population are visually and mechanically (for gray cast iron and ductile iron components) inspected at each unit. When inspections are conducted on piping, a 1-foot axial length section is considered as one inspection. In addition, for sample populations with greater than 35 susceptible components, two destructive examinations are performed in each material and environment population in each 10-year period at each unit. When there are less than 35 susceptible components in a sample population, one destructive examination is performed for that population. Otherwise, a technical justification of the methodology and sample size used for selecting components for inspection is included as part of the program’s documentation. The number of visual and mechanical inspections may be reduced by two for each component that is destructively examined beyond the minimum number of destructive examinations recommended in each 10-year interval. Inspections, where possible, focus on the bounding or lead components most susceptible to aging based on time-in-service and severity of operating conditions for each population. Opportunistic inspections may be credited as periodic inspections as long as the inspection locations selection criteria are met.
For multi-unit sites where the sample size is not based on the percentage of the population and the inspections are conducted periodically (not one-time inspections), it is acceptable to reduce the total number of inspections at the site as follows. For two unit sites, eight visual and mechanical inspections and two destructive examinations are conducted at each unit. For two unit sites with less than 35 susceptible components in a sample population at each unit, one destructive examination is performed for that sample population. For three unit sites, seven visual and mechanical and one destructive examination are conducted at each unit. In order to conduct the reduced number of inspections, the applicant states in the SLRA the basis for why the operating conditions at each unit are similar enough (e.g., flowrate, chemistry, temperature, excursions) to provide representative inspection results. The basis should include consideration of potential differences such as the following:
  • Have power uprates been performed and if so, could more aging have occurred on one unit that has been in the uprate period for a longer time period?
  • Are there any systems which have had an out-of-spec water chemistry condition for a longer period of time or out-of-spec conditions occurred more frequently?
  • For raw water systems, is the water source from different sources where one or the other is more susceptible to microbiologically influenced corrosion or other aging effects?
For raw water and waste water environments, the populations may be combined as long as an evaluation is conducted to determine the more severe environment and the inspections and examinations are conducted on components in the most severe environment, with one inspection being conducted in the less severe environment.
Dependent on plant-specific OE and implementation of preventive actions, the exclusions for external surface coatings of buried components may no longer apply and the inspection population is adjusted as follows. When minor through coating damage has been identified in plant-specific OE, but the components are coated in accordance with Table XI.M41-1 of GALL-SLR Report AMP XI.M41, the inspection sample size may be reduced by 50 percent (inspection quantities are rounded up) of that recommended in the “detection of aging effects” program element of this AMP if the following conditions are met:
  • There were no more than two instances of coating damage identified in each 10-year period of the prior operating period
  • An analysis demonstrates that, if the pipe surface area affected by the coating damage is assumed to have been a through-wall hole, the pipe could be shown to meet unreinforced opening criteria of the applicable piping code
Inspections follow site procedures that include inspection parameters such as lighting, distance, offset, surface coverage, presence of protective coatings, and cleaning processes.
5. Monitoring and Trending: Where practical, identified degradation is projected until the next scheduled inspection. Results are evaluated against acceptance criteria to confirm that the sampling bases (e.g., selection, size, frequency) will maintain the components’ intended functions throughout the subsequent period of extended operation based on the projected rate and extent of degradation.
6. Acceptance Criteria: The acceptance criteria are: (a) for copper-based alloys, no noticeable change in color from the normal yellow color to the reddish copper color or green copper oxide; (b) for gray cast iron and ductile iron, the absence of a surface layer that can be easily removed by chipping or scraping or identified in the destructive examinations, (c) the presence of no more than a superficial layer of dealloying, as determined by removal of the dealloyed material by mechanical removal, and (d) the components meet system design requirements such as minimum wall thickness, when extended to the end of the subsequent period of extended operation. When evaluating a component in relation to criterion (c) no credit is used for the material properties of the dealloyed portion of the component.
7. Corrective Actions: Results that do not meet the acceptance criteria are addressed in the applicant’s corrective action program under those specific portions of the quality assurance (QA) program that are used to meet Criterion XVI, “Corrective Action,” of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B. Appendix A of the GALL-SLR Report describes how an applicant may apply its 10 CFR Part 50, Appendix B, QA program to fulfill the corrective actions element of this AMP for both safety-related and nonsafety-related structures and component (SCs) within the scope of this program.
When the acceptance criteria are not met such that it is determined that the affected component should be replaced prior to the end of the subsequent period of extended operation, additional inspections are performed if the cause of the aging effect for each applicable material and environment is not corrected by repair or replacement for all components constructed of the same material and exposed to the same environment. The number of additional inspections is equal to the number of failed inspections for each material and environment population with a minimum of five additional visual and mechanical inspections when visual and mechanical inspections(s) did not meet acceptance criteria, or 20 percent of each applicable material and environment combination is inspected, whichever is less, and a minimum of one additional destructive examination when destruction examination(s) did not meet acceptance criteria. If subsequent inspections do not meet acceptance criteria, an extent of condition and extent of cause analysis is conducted to determine the further extent of inspections. The timing of the additional inspections is based on the severity of the degradation identified and is commensurate with the potential for loss of intended function. However, in all cases, the additional inspections are completed within the interval in which the original inspection was conducted or, if identified in the latter half of the current inspection interval, within the next refueling outage interval. These additional inspections conducted in the next inspection interval cannot also be credited towards the number of inspections in the latter interval. Additional samples are inspected for any recurring degradation to ensure corrective actions appropriately address the associated causes. At multi-unit sites, the additional inspections include inspections at all of the units with the same material, environment, and aging effect combination.
The program includes a process to evaluate difficult-to-access surfaces (e.g., heat exchanger shell interiors, exterior of heat exchanger tubes) if unacceptable inspection findings occur within the same material and environment population.
8. Confirmation Process: The confirmation process is addressed through those specific portions of the QA program that are used to meet Criterion XVI, “Corrective Action,” of 10 CFR 50, Appendix B. Appendix A of the GALL-SLR Report describes how an applicant may apply its 10 CFR 50, Appendix B, QA program to fulfill the confirmation process element of this AMP for both safety-related and nonsafety-related SCs within the scope of this program.
9. Administrative Controls: Administrative controls are addressed through the QA program that is used to meet the requirements of 10 CFR 50, Appendix B, associated with managing the effects of aging. Appendix A of the GALL-SLR Report describes how an applicant may apply its 10 CFR 50, Appendix B, QA program to fulfill the administrative controls element of this AMP for both safety-related and nonsafety-related SCs within the scope of this program.
10. Operating Experience: OE shows that selective leaching has been detected in components constructed from gray cast iron, ductile iron, brass, bronze, and aluminum bronze. The following OE may be of significance to an applicant’s program:
  1. In March 2013, a licensee submitted an American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) Section XI relief request because it had detected weeping through aluminum bronze (susceptible to dealloying) valve bodies exposed to sea water. The degraded area was characterized by corrosion debris or wetness that returned following cleaning and drying of the surface. [Agencywide Documents Access and Management System (ADAMS) Accession No. ML13091A038 and ML14182A634].
  2. During a one-time inspection for selective leaching, a licensee identified degradation in four gray cast iron valve bodies in the service water system exposed to raw water. The mechanical test used by the licensee to identify the graphitization was tapping and scraping of the surface. The licensee sand blasted two of the valve bodies and, after all of the graphite was removed; the licensee determined that the leaching progressed to a depth of approximately 3/32 inch. Based on the estimated corrosion rate, the licensee determined that the valve bodies had adequate wall thickness for at least 20 years of additional service. (ADAMS Accession No. ML14017A289).
  3. Based on visual inspections conducted as part of implementing a one-time inspection for selective leaching, a licensee identified selective leaching in a gray cast iron drain plug of an auxiliary feedwater pump outboard bearing cooler. Possible selective leaching was also found on multimatic valves on the underside of the clapper. As a result, the licensee incorporated quarterly inspections of the components in its periodic surveillance and preventive maintenance program. (ADAMS Accession No. ML13122A009).
  4. In September 2008, a licensee identified the dealloying of an aluminum bronze strainer drum exposed to brackish water. This was identified after an unexpected material failure occurred, during a planned maintenance evolution at an offsite repair facility. The maintenance evolution involved rigging the strainer drum into position for a machining operation. During the rigging, the strainer drum material failed at the rigging attachment point to the strainer. This failure of the strainer drum exposed the inner portion of the drum material where dealloying of the drum was visually observed during an inspection. (ADAMS Accession No. ML092400531).
  5. A licensee has reported occurrences of selective leaching of aluminum bronze components for an extensive number of years. (ADAMS Accession No. ML17142A263).
  6. U.S. Nuclear Regulatory Commission (US NRC) Information Notice (IN) 84-71, Graphitic Corrosion of Cast Iron in Salt Water,] September 06, 1984.
  7. US NRC IN 94-59, Accelerated Dealloying of Cast Aluminum-Bronze Valves Caused by Microbiologically Induced Corrosion, August 17, 1994.
  8. The basis for inclusion of ductile iron in this GALL-SLR Report AMP XI.M33, along with OE examples, is cited in the GALL-SLR and SRP-SLR Supplemental Staff Guidance document. (ADAMS Accession No. ML16041A090).
The program is informed and enhanced when necessary through the systematic and ongoing review of both plant-specific and industry OE including research and development such that the effectiveness of the AMP is evaluated consistent with the discussion in Appendix B of the GALL-SLR Report.


References

10 CFR Part 50, Appendix B, “Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants.” Washington, DC: U.S. Nuclear Regulatory Commission. 2016.

EPRI. EPRI TR–107514, “Age Related Degradation Inspection Method and Demonstration.” Palo Alto, California: Electric Power Research Institute. April 1998.

Fontana, M.G. Corrosion Engineering. McGraw Hill. pp. 86-90. 1986.

US NRC. “GALL-SLR and SRP-SLR Supplemental Staff Guidance.” Agencywide Documents Access and Management System (ADAMS) Accession No. ML16041A090. Washington, DC: U.S. Nuclear Regulatory Commission. March 2016.