XI.M32 (NUREG-1801 R0)

From EPRI Nuclear LTO Wiki
Jump to navigation Jump to search

Return to AMP Table


XI.M32 ONE-TIME INSPECTION

Program Description

The program includes measures to verify the effectiveness of an aging management program (AMP) and confirm the absence of an aging effect. For example, for structures and components that rely on an AMP, such as water chemistry control, this program verifies the effectiveness of the AMP by confirming that unacceptable degradation is not occurring and the intended function of a component will be maintained during the extended period of operation. One-time inspection is needed to address concerns for the potential long incubation period for certain aging effects on structures and components. There are cases where either (a) an aging effect is not expected to occur but there is insufficient data to completely rule it out, or (b) an aging effect is expected to progress very slowly. For these cases, there is to be confirmation that either the aging effect is indeed not occurring, or the aging effect is occurring very slowly as not to affect the component or structure intended function. A one-time inspection of the subject component or structure is an acceptable option for this verification. One-time inspection is to provide additional assurance that either aging is not occurring or the evidence of aging is so insignificant that an aging management program is not warranted. For example, for structures and components, such as Class 1 piping with a diameter less than nominal pipe size (NPS) 4 inch that do not receive volumetric examination during inservice inspection, the program confirms that crack initiation and growth due to stress corrosion cracking (SCC) or cyclic loading is not occurring and, therefore, there is no need to manage an aging related degradation for the period of extended operation.

The elements of the program include (a) determination of the sample size based on an assessment of materials of fabrication, environment, plausible aging effects, and operating experience; (b) identification of the inspection locations in the system or component based on the aging effect; (c) determination of the examination technique, including acceptance criteria that would be effective in managing the aging effect for which the component is examined; and (d) evaluation of the need for follow-up examinations to monitor the progression of any aging degradation.

When evidence of an aging effect is revealed by a one-time inspection, the routine evaluation of the inspection results would identify appropriate corrective actions.

As set forth below, an acceptable verification program may consist of a one-time inspection of selected components and susceptible locations in the system. An alternative acceptable program may include routine maintenance or a review of repair records to confirm that these components have been inspected for aging degradation and significant aging degradation has not occurred and thereby verify the effectiveness of existing AMPs. One-time inspection, or any other action or program, is to be reviewed by the staff on a plant-specific basis.


Evaluation and Technical Basis

1. Scope of Program: The program includes measures to verify that unacceptable degradation is not occurring, thereby validating the effectiveness of existing AMPs or confirming that there is no need to manage aging-related degradation for the period of extended operation. The structures and components for which one-time inspection is to verify the effectiveness of the AMPs (e.g., water chemistry control, etc.) have been identified in the Generic Aging Lessons Learned (GALL) report. Examples include small bore piping in the reactor coolant system or the feedwater system components in boiling water reactors (BWRs) and pressurized water reactors (PWRs).
2. Preventive Actions: One-time inspection is an inspection activity independent of methods to mitigate or prevent degradation.
3. Parameters Monitored/Inspected: The program monitors parameters directly related to the degradation of a component. Inspection is performed in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Code and 10 CFR 50, Appendix B, by using a variety of nondestructive examination (NDE) methods, including visual, volumetric, and surface techniques.
4. Detection of Aging Effects: The inspection includes a representative sample of the system population, and, where practical, focus on the bounding or lead components most susceptible to aging due to time in service, severity of operating conditions, and lowest design margin. For small-bore piping, actual inspection locations are based on physical accessibility, exposure levels, NDE techniques, and locations identified in U.S. Nuclear Regulatory Commission (US NRC) Information Notice (IN) 97-46.
Combinations of NDE, including visual, ultrasonic, and surface techniques, are performed by qualified personnel following procedures consistent with the ASME Code and 10 CFR 50, Appendix B. For small-bore piping less than NPS 4 in., including pipe, fittings, and branch connections, a plant-specific destructive examination of replaced piping due to plant modifications or NDE that permits inspection of the inside surfaces of the piping is to be conducted to ensure that cracking has not occurred. Follow-up of unacceptable inspection findings includes expansion of the inspection sample size and locations.
The inspection and test techniques prescribed by the program verify any aging effects because these techniques, used by qualified personnel, have been proven effective and consistent with staff expectations. With respect to inspection timing, the one-time inspection is to be completed before the end of the current operating license. The applicant may schedule the inspection in such a way as to minimize the impact on plant operations. However, the inspection is not to be scheduled too early in the current operating term, which could raise questions regarding continued absence of aging effects prior to and near the extended period of operation.
5. Monitoring and Trending: One-time inspection does not provide specific guidance on monitoring and trending. However, evaluation of the appropriateness of the techniques and timing of the one-time inspection improve with the accumulation of plant-specific and industry-wide experience.
6. Acceptance Criteria: Any indication or relevant conditions of degradation detected are evaluated. The ultrasonic thickness measurements are to be compared to predetermined limits, such as design minimum wall thickness.
7. Corrective Actions: Site quality assurance (QA) procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR 50, Appendix B. As discussed in the appendix to this report, the staff finds the requirements of 10 CFR 50, Appendix B, acceptable in addressing the corrective actions, confirmation process, and administrative controls.
8. Confirmation Process: See Item 7, above.
9. Administrative Controls: See Item 7, above.
10. Operating Experience: One-time inspection is a new program to be applied by the applicant. The elements that comprise these inspections (e.g., the scope of the inspections and inspection techniques) are consistent with years of industry practice and staff expectations.


References

10 CFR 50.55a, Codes and Standards, Office of the Federal Register, National Archives and Records Administration, 2000.

ASME Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, ASME Boiler and Pressure Vessel Code, 1995 edition through the 1996 addenda, American Society of Mechanical Engineers, New York, NY.

US NRC Information Notice 97-46, Unisolable Crack in High-Pressure Injection Piping, U.S. Nuclear Regulatory Commission, July 9, 1997.